Only Water Dispensed; No Concentrate Or Water; Dispensed; Trate ''Ratio - Cornelius TEA URN Service Manual

Post-mix
Table of Contents

Advertisement

Trouble

ONLY WATER DISPENSED.

ONLY CONCENTRATE

DISPENSED.

NO CONCENTRATE OR
WATER DISPENSED.
312020000
Probable Cause
A.
Connections not secure on
bag-in-box container.
B.
Out of concentrate.
C.
Concentrate pump primary
CO
gas regulator not properly
2
adjusted.
D.
Inoperable dispensing valve.
E.
Dispensing valve concentrate
flow regulator not properly
adjusted.
F.
No CO
gas supply.
2
G.
Dispensing valve concentrate
flow regulator, bag-in-box
quick disconnect, or
concentrate lines restricted.
H.
Inoperable Concentrate Pump.
A.
Plain water source line shutoff
valve closed.
B.
Water filter clogged.
A.
Inoperable dispensing valve.
12
Remedy
A.
Secure connections on bag-in-box
Container.
B.
Replenish concentrate supply as
instructed.
C.
Adjust primary CO
2
as instructed.
D.
Call a qualified Service Person.
E.
Adjust Water-to-Concentrate
''Ratio'' of dispensed product as
instructed.
F.
Replenish CO
gas supply as
2
instructed.
G.
Sanitize concentrate system as
instructed.
H.
Replace Concentrate Pump.
(call a qualified Service Person)
A.
Open plain water source line
shutoff valve.
B.
Replace water filter cartridge.
A.
Repair dispensing valve.
(call a qualified Service Person)
gas regulator

Advertisement

Table of Contents
loading

Table of Contents