2.3.5
How to connect operator fitness to a BR-500
Note: Operator fitness does not require menu settings.
1. Referring to the figure below, place heat shrink tubes on the wires, then solder the
connection point. (Refer to the BR-500 installer's manual for the appropriate wires
at the BR-500.)
2. Move the heat shrink tubes to the soldered connection, then apply heat to the
tubes.
3. Secure any unused wires, referring to "How to isolate and secure unused
wires" on page 2-3.
Secure unused
wires with tape here
2.4

Network Connector

Like previous NavNet series equipment, the TZTL12F and TZTL15F may share Radar
and Fish Finder images, and other information, across a TCP/IP Ethernet connection.
Up to four NavNet TZtouch2 units may be connected to the same network at one time.
Both the TZTL12F and TZTL15F are equipped with a network connector (RJ45).
2.5

Video In, Video Out and USB Connections

The composite 2 bundle, at the rear of the unit (See the figure on page 2-1), contains
connection leads for Video In (two leads), one HDMI output and one USB port.
Analog video input
The NavNet TZtouch2 can use regular analog video inputs (PAL or NTSC) that
connect to the NavNet TZtouch2 directly via the Video Input 1/2 connectors. Analog
video can be viewed only on the equipment where the source is connected.
Additionally FLIR cameras may be connected to the NavNet TZtouch2. Connect the
Video Out cable from the camera to the Video In (1 or 2) cable on the NavNet
TZtouch2.
Note: Some camera models may require an adapter for connection.
Cameras may be set up using the appropriate menu item on the [Camera] menu,
accessed from the [Settings] menu. For details on camera setup, see the operator's
manual (OME-44870-x)
Note: IP cameras cannot be connected to the TZTL12F or TZTL15F.