Calibration parameter
Parameter
Indication
C1
FM terminal calibration
(900)
C2
Frequency setting
voltage bias frequency
(902)
C3
Frequency setting
voltage bias
(902)
C4
Frequency setting
voltage gain
(903)
C5
Frequency setting
current bias frequency
(904)
C6
Frequency setting
current bias
(904)
C7
Frequency setting
current gain
(905)
C8
(269)
CLr
Parameter clear
ECL
Alarm history clear
*Settings may differ because of calibration parameters.
Name
You can calibrate the indicator connected
to across terminals FM-SD.
You can set as desired the magnitude
(slope) of the output frequency to the
external frequency setting voltage signal
(0 to 5V or 0 to 10V). (Bias frequency)
0 to 60Hz
Used to adjust the analog-to-digital
converted voltage value of the frequency
set in calibration parameter C2. (Bias %)
0 to 300%
Used to adjust the analog-to-digital
converted voltage value of the frequency
set in Pr. 38. (Gain %)
0 to 300%
You can set as desired the magnitude
(slope) of the output frequency to the
external frequency setting current signal
(4 to 20mA).
0 to 60Hz
Used to adjust the analog-to-digital
converted voltage value of the frequency
set in calibration parameter C5. (Bias %)
0 to 300%
Used to adjust the analog-to-digital
converted voltage value of the frequency
set in Pr. 39. (Gain %)
0 to 300%
Parameter for manufacturer setting. Do not set.
0: Not executed
1: Initialization of parameters other than
calibration values (parameter clear)
10: Initialization of parameters including
calibration values (all clear)
0: Not cleared
1: Alarm history clear
41
Extended function parameter list
Description
Factory
Setting
0Hz
0%*
96%*
0Hz
20%*
100%*
0
0
6