Parameter
Indication
71
Applied motor
PWM frequency
72
selection
73
0-5V/0-10V selection
Input filter time
74
constant
Reset selection/PU
75
stop selection
Cooling fan operation
76
selection
Name
Set the motor to be used.
0, 100: Thermal characteristic for
1, 101: Thermal characteristic for
When "100 or 101" is set, turning on the RT
signal set the electronic thermal relay
function to the thermal characteristic for the
constant-torque motor.
You can change the PWM carrier
frequency. Increasing this value reduces
the motor audible noise, but increases
noise and leakage current.
The setting is in [kHz].
0: 0.7kHz, 15: 14.5kHz
0 to 15
(Remarks)Metallic sound may be
You can set the input voltage specification
of terminal "2".
0: For 0 to 5VDC input, 1: For 0 to 10VDC
input
Valid for eliminating noise of the frequency
setting circuit.
A larger set value increases the time
constant.
0 to 8
You can choose the function of the
on the operation panel.
0
Normally enabled
Enabled only when the
1
protective function is
activated
14 Normally enabled
Enabled only when the
15
protective function is
activated
You can control the operation of the cooling
fan built in the inverter. (Operates in power-
on status.)
0: The fan normally operates at power on
of the inverter.
1: The fan is normally on during inverter
operation. The fan switches on/off
according to the temperature during a
stop of the inverter whose status is
monitored.
Extended function parameter list
Description
Mitsubishi standard motor
Mitsubishi constant-torque motor
generated from the motor at
sudden deceleration but it is not
a fault.
Reset Input
PU stop key Input
Invalid (Valid only in
the PU operation
mode or combined
operation mode
(Pr. 79=4))
Valid
37
Factory
Setting
0
1
0
1
STOP
RESET
14
1
6