u s e r g u i d e
Vogue Combi c26, c32, c40
When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and
performance specification that we require.
Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.

Advertisement

Table of Contents
loading

Summary of Contents for IDEAL Vogue Combi c26

  • Page 1 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.
  • Page 3: Natural Gas Only

    G.C. Appliance No. 47-348-98 G.C. Appliance No. 47-348-97 Ideal Stelrad Group is a member of the Benchmark scheme and fully supports the aims of the programme. Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency.
  • Page 4 FOR ANy qUERIES PLEASE RING THE IDEAL CONSUMER HELPLINE : 01482 498660 NOTE. BOILER RESET PROCEDURE - To reset boiler, press button “r” on the control panel. The boiler will repeat the ignition sequence if a heat demand is present...
  • Page 5: Important Notes

    IMPORTANT NOTES • This appliance must not be operated without the casing correctly fitted and forming an adequate seal. • If the boiler is installed in a compartment then the compartment mUST noT be used for storage purposes. • If it is known or suspected that a fault exists on the boiler then it MUST NOT BE USED until the fault has been corrected by a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII).
  • Page 6: Boiler Controls

    BOILER CONTROLS LEGEND Boiler Status Exit Button C. Down Button D. Up Button Enter Button Reset Button 60°C G. CH Temperature Control H. DHW Temperature Control and off Switch Burner on indication Pressure Gauge Boiler in Full Condensing mode...
  • Page 7 TO LIGHT THE BOILER. (REFER TO BOILER CONTROLS) If a programmer is fitted refer to separate instructions for the If the boiler has not lit, after 5 ignition attempts, the following programmer before continuing. screen will be displayed. Switch on electricity to the boiler and check that all Ignition Lockout external controls, e.g.
  • Page 8: Operation

    OPERATION CONTROL OF WATER TEMPERATURE CH and DHW required. Domestic Hot Water The boiler will fire and supply heat to the radiators but will give The DHW temperature is limited by the boiler controls to priority to DHW on demand. C maximum at low draw-off rate, adjustable via the DHW temperature control (H).
  • Page 9: To Shut Down The Boiler

    TO SHUT DOWN THE BOILER Set the DHW temperature control knob to oFF. TO RELIGHT THE BOILER Repeat the procedure detailed in ‘To light the boiler’. Set the DHW temperature control knob to between min & max. FROST PROTECTION If no frost protection is provided and frost is likely during a short absence from home, leave the heating controls (if fitted) at a reduced temperature setting.
  • Page 10: Loss Of System Water Pressure

    LOSS OF SySTEM WATER PRESSURE The gauge (K ref page 6) indicates the central heating system pressure. If the pressure is seen to fall below the original installation pressure of 1-2 bar then conduct the re-pressurising procedure as shown below. If unable to do so or if the pressure continues to drop a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII) should be consulted.
  • Page 11: Condensate Drain

    CONDENSATE DRAIN closely as possible before taking further action. 2. Apply a hot water bottle, microwaveable heat pack or a This appliance is fitted with a siphonic condensate trap warm damp cloth to the frozen blockage area. Several system that reduces the risk of the appliance condensate applications may have to be made before it fully defrosts.
  • Page 12: Points For The Boiler User

    POINTS FOR THE BOILER USER Note. In line with our current warranty policy we would ask that you check through the following guide to identify any problems external to the boiler prior to requesting a service engineers visit. Should the problem be found to be other than with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is not gained by the engineer.
  • Page 13: Fault Finding

    FAULT FINDING If a fault occurs then a fault description and suggested potential corrective actions will be displayed. In addition the following information may be useful. Too many resets 5 boiler faults have been reset within a 15 min period. It is recommended that the boiler should be examined by a suitably qualified service engineer.
  • Page 14 BOILER CONTROLS LEGEND Boiler Status Exit Button C. Down Button D. Up Button Enter Button Reset Button 60°C G. CH Temperature Control H. DHW Temperature Control and off Switch Burner on indication Pressure Gauge Boiler in Full Condensing mode...
  • Page 15: Display Functions In Normal Operation

    DISPLAy FUNCTIONS IN NORMAL OPERATION Indicates that the Boiler is providing Central Heating Indicates that the Boiler is Switched off and that the radiator temperature is 60°C move the DHW Dial (H) clockwise to switch the Boiler on 60°C Indicates that Central Heating has been switched off Indicates that the Boiler is pre-heating at the Boiler To Switch Pre-heat off, see page 17 - Pre-heat...
  • Page 16: Change Setting

    CHANGE SETTING To change the Hot Water To disable DHW and CH (frost Temperature rotate the DHW Dial protection still active) rotate the °C DHW Dial fully anti-clockwise This screen will be shown This screen will be shown Select Hot Water Temperature Boiler Switched Off To change the Maximum Radiator To switch the boiler on rotate...
  • Page 17: Menu Operation

    MENU OPERATION Pre-heat Efficiency Level If pre-heat is switched on then the boiler will periodically fire the To view the efficiency level of the boiler press ENTER and the burner thereby reducing the time taken to provide hot water. If following screen will be displayed.
  • Page 18 MENU OPERATION Reset Service Time System Frost Protection If the boiler has not been serviced within the last 12 months then This feature can only be accessed if an outside sensor has a message will be displayed indicating this. To reset this timing been connected.
  • Page 19 MENU OPERATION Set Zone 2 Flow Temperature If a second switched live is connected to the boiler for a second heating zone then the flow temperature target for this zone can be set independently. Press EnTER and the following screen will be displayed.
  • Page 20 Ideal Stelrad Group, pursues a policy of continuing improvement in the design and performance of its products. The right is therefore reserved to vary specification without notice. Ideal, P.O. Box 103, National Ave, Kingston Upon Hull, HU5 4JN. Tel. 01482 492251 Fax. 01482 448858. Registration No. London 322 137.