Wireless room thermostat with hot water control (dhw & single zone ch) logic heat h / logic max heat h / logic system s / logic max system s / vogue system / vogue max system (30 pages)
Electronic programmer, 7 day for boiler (16 pages)
Summary of Contents for IDEAL RF Electronic
Page 1
When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.
RF Electronic Programmable Room Thermostat, 7 Day Contents Page Summer/Winter Time (GMT/BST) - automatically updated Programmable Room Thermostat ......4 Boiler temperature minimised to reduce gas consumption Transceiver Unit ............5 Room Temperature ..........6 Radio Frequency Communication (no wiring) Timed/On/Off ............
back Programmable Room Thermostat Time Program Time Day of the week Operating Mode Room Temperature Control Battery Wireless Connection Room Temperature Hot Keys Note: if the Low Battery symbol is visible or the display is blank then replace the batteries...
back Transceiver (Boiler Mounted) 1 During normal operation light (A) is on for Hot Water operation. 2 During normal operation light (B) is on for Central Heating operation. 3 If the Reset Button is pressed on the room thermostat the signal lights on the receiver unit will light. If less than 4 lights are on either the room thermostat is too far from the boiler or the batteries in the room thermostat need replacing.
back Room Temperature To set the Room Temperature, rotate the Knob until the desired temperature is shown. Note that this temperature can only be changed if there is an ongoing demand for Central Heating. To set different temperatures for different time periods see Advanced Temperatures Room Temperature Control...
back Timed, Continuously On and Continuously Off operation To set the Room Stat for Timed operation press MODE until “TIMED ON” or “TIMED OFF” is shown. To set the Room Stat to be Continuously On To set the Room Stat to be Continuously Off press MODE until “CONT ON”...
back + Hours If + Hours is used during an off period, the boiler will then operate for up to 5 hours. If + Hours is used during an on period, the on period will be extended by up to 5 hours. To set + Hours press +HOURS and this screen will be shown.
back Time/Date Summer/Winter time is automatically updated At installation the “SET TIME/DATE” menu option activates automatically (starts at step 2) 1. Press MENU and this 5. Press OK and this screen will be displayed screen will be displayed. Press “+” and “-” until the current YEAR is shown.
back On/Off Times 1 To set On/Off Times, 5 Press “+” and “-” until press MENU and this the desired Hours figure is screen will be displayed, shown and then press OK Press “+” and “-” until the then press OK. desired Minutes figure is 2 Press “+”...
back Holiday Mode 1 Press MENU and this 5. Press OK and this screen will be shown. screen will be shown. Press “+” and “-” until the desired Holiday Month is shown. 2 Press NEXT until this 6. Press OK and this screen is shown.
back Advanced Temperatures It is possible to set 3 different room temperature set points for the 3 different On/Off times as follows 1 Press MENU and this 5 Press OK and this screen will be shown. Press “+” screen will be shown. and “-”...
back Optimisation Optimisation provides for greater comfort and economy of operation. The boiler will be switched on earlier than the programmed heating on time. This provides for the room temperature to be achieved at the programmed heating on time rather than some time afterwards. The boiler will automatically only use the minimum energy required in order to achieve the desired room temperature.
back Service Required Indication The Room Stat can be set so that after a pre-determined period a message will be displayed indicating that a Service of the Central Heating system is due. The factory setting is that this feature is disabled. After being enabled the feature can be disabled by setting the feature to 0.
back Display Backlight Intensity To change the LCD backlight intensity proceed as follows. 1 Press MENU and this screen will be shown. 2 Press NEXT until this screen is shown. 3 Press OK and this screen will be shown, then press “+” or “-” until the required setting is shown.
back Reset To Factory Settings The Room Stat can be returned to Factory Settings as follows. 1 Press MENU and this screen will be shown. 3 Press OK and this screen will be shown. 4 Press OK to Reset and this screen will be briefly 2 Press NEXT until this screen is shown.
back Fault Help Boiler fault codes are identified on the display in plain English, they are also supported with a suggested corrective action to aid diagnostics Fault Potential Corrective Actions Overheat Lockout Fill system to 1 Bar Bleed radiators, refill system Check radiator valves are open Reset boiler by pressing r Ignition Lockout...
Page 18
back Fault Help Boiler fault codes are identified on the display in plain English, they are also supported with a suggested corrective action to aid diagnostics Fault Potential Corrective Actions PCB Replaced Incorrectly Contact installer Low Mains Voltage Contact electricity provider Low Water Pressure Fill system to 1 Bar Bleed radiators...
back Efficiency The Room Stat uses the OpenTherm protocol to control the boiler flow temperature set point in central heating operation. This means that the boiler will run in its most efficient manner and offer significant savings in energy usage over standard room thermostats. It will also give more accurate and comfortable temperature control.
August 2012 UIN 208900 A01 Ideal Stelrad Group pursues a policy of continuing improvement in the design and performance of its products. The right is therefore reserved to vary specification without notice. Ideal, P.O. Box 103, National Ave, Kingston Upon Hull, HU5 4JN. Tel. 01482...