Clearance To Combustibles; Mantels; Hearth - Majestic fireplaces 33LDVR Installation Instructions And Homeowner's Manual

Builder rear vent direct vent
Table of Contents

Advertisement

Clearance to Combustibles

Top of Unit to Ceiling ............................. 36" (914mm)
Appliance
Top ....................................................... 0" (0 mm)
Bottom .................................................. 0" (0 mm)
Side ...................................................... 0" (0 mm)
Back ..................................................... 0" (0 mm)
Venting
Concentric sections of DV Vent
Top, bottom & sides ........................... 1" (25 mm)
Rear Vent Applications:
Top ..................................................... 2" (50 mm)
Sides and Bottom ............................... 1" (25 mm)
The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.
For the correct mounting height and widths refer to
Figs. 3a and 3b, and the following Mantel Charts.
The fitting of a bay window trim kit does not effect
the distances and reference points referred to in the
diagram and chart.
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
When using paint or lacquer to finish the mantel, such
paint or lacquer must be heat resistant to prevent
discoloration.
A
B
C
Mantel Chart
Mantel Shelf
Ref. or Breast Plate Ref.
Depth
V
10" (254 mm)
A
W
8" (203 mm)
B
X
6" (152 mm)
C
Y
4" (101 mm)
D
Z
2" (50 mm)
E
Fig. 3a Combustible mantel minimum installation.
10007317

Mantels

V
W
X
Y
Z
D
E
Fireplace
Top Louvre As-
sembly
Top of Combustion
Chamber
CFM146
DV Mantel Chart
7/5/01 sta
Mantel from Top
of Combustion Chamber
36/39/43 LDVR
33LDVR
17" (432 mm)
16¹⁄₂" (419 mm)
15" (381 mm)
14¹⁄₂" (368 mm)
13" (330 mm)
12¹⁄₂" (318 mm)
11" (279 mm)
10¹⁄₂" (267 mm)
9" (229 mm)
8¹⁄₂" (216 mm)
LDVR Series Direct Vent Gas Fireplace
Black
Surround
Face
CFM164a
Side of
Combustion Chamber
CFM164a
Mantel Leg Chart
06/22/01 sta
Ref.
F
10" (254mm)
G
8" (203mm)
H
6" (152mm)
I
4" (101mm)
J
Fig. 3b Combustible mantel leg minimum installation.
A hearth is not mandatory but is recommended for
aesthetic purposes. We recommend a noncombustible
hearth which projects out 12" (305mm) or more from
the front of the fireplace.
Cold climate installation recommendation:
When installing this unit against a
non-insulated exterior wall or chase,
CFM146
it is mandatory that the outer walls
be insulated to conform to applicable
insulation codes.
This appliance may be installed in an aftermarket
permanently located, manufactured home or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated
on the rating plate. This appliance is not convertible for
use with other gases, unless a certified kit is used.
The LDVR has been approved for mobile home
installations.
Mantel
Leg
Mantel
Mantel Leg FromSide
Leg Depth
Ref.
of Comb. Opening
CFM170
K
DV Builder Front
L
View
M
N
2" (50mm)
O

Hearth

J
I
H
G
F
K
L
M
N
O
CFM170
11¹⁄₂" (292 mm)
9¹⁄₂" (241 mm)
7¹⁄₂" (191 mm)
5¹⁄₂" (140 mm)
3¹⁄₂" (89 mm)
5