Vertical Sidewall Applications & Installation - Majestic fireplaces 33LDVR Installation Instructions And Homeowner's Manual

Builder rear vent direct vent
Table of Contents

Advertisement

LDVR Series Direct Vent Gas Fireplace
Zero
Clearance
Sleeve
Fig. 17 Firestop and zero clearance sleeve in place.
CFM133
DVR Series Typical corner install
2/26/01 sta
Finished Wall
Fig. 18 Side view of final unit location.
FP1005
Rear Wall Vent Installations -
Side View Vent Termination
Flex Vent Pipe
1/25/00 djt
Follow Steps 1 and 2 on Page 13.
Step 3
Install the 4" (102mm) flex vent pipe to the appliance
collars described in "General Information Assembling
Vent Pipes", Page 11. If the installation requires a 45°
angle, grasp the vent pipe close to the appliance collar
and bend to 45°. DO NOT exceed 45°. (Fig. 19)
Install the 7" vent pipe in the same manner as Step 2.
NOTE: There must be a 1" (25mm) rise in a 24"
(610mm) length of flex vent.
Step 4
Assemble the flex vent to the collars on the termination
as you did on the appliance.
14
Firestop
CFM133
Fig. 19 Grasp the vent pipe close to the collar and bend to
45° angle. Do not exceed 45°.
Vent Termi-
nation
Fig. 20 There must be a 1/2" rise per foot length.
FP1005
The Vent Graph shows the relationship between vertical
and horizontal side wall venting and will help to deter-
mine the various dimensions allowable.
When vent termination exits through foundations less
than 20" below siding outcrop, the vent pipe must
flush up with the siding. It is always best to locate the
fireplace in such a way that minimizes the number of
offsets and horizontal vent length.
The horizontal vent run refers to the total length of vent
pipe from the flue collar of the fireplace to the face of
the outer wall.
Termination
Flex Section
Appliance Collars
FP1473
corner flex install
4/04 djt
Vertical Sidewall Applications
Since it is very important that the vent-
ing system maintain its balance between
the combustion air intake and the flue
gas exhaust, certain limitations as to vent
FP1472
configurations apply and must be strictly
rise in length
adhered to.
4/04 djt
Minimum clearance between vent pipes
and combustible materials is 1"(25mm) on
top, bottom and sides unless otherwise
noted.
FP1473
Rise
FP1472
10007317