Clearance To Combustibles; Mantels; Hearth - Majestic fireplaces NVC36 Installation And Homeowners Operating Instructions

Decorative gas appliance
Hide thumbs Also See for NVC36:
Table of Contents

Advertisement

Clearance to Combustibles

Appliances
Top ........................................... 0" (0mm)
Bottom ..................................... 0" (0mm)
Side ......................................... 0" (0mm)
Back ......................................... 0" (0mm)
Perpendicular Sidewall ............ 0" (0mm)
Top of unit to ceiling ................. 36" (914mm)
Front of unit to combustibles ... 36" (914mm)
Venting
B-Vent ...................................... 1" (25mm)

Mantels

The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.
For the correct mounting height and widths refer to
Figures 2a and 2b and the Mantel Chart below.
The distances and reference points are not affected by
the fitting of a bay window front trim kit.
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
When using a paint or lacquer to finish the mantel, such
paint or lacquer must be heat resistant to prevent
discoloration.
Side View
A
B
C
D
E
Bottom of Door Trim
Ref.
Mantel
Shelf Depth
V
10" (254 mm)
W
8" (203 mm)
X
6" (152 mm)
Y
4" (101 mm)
Z
2" ( 51 mm)
Fig. 2a Mantel clearances.
20000194
V
W
X
Y
Z
Fireplace
Top Louvre Assembly
Top of
Combustion Chamber
Ref.
Mantel From Top
of Comb. Chamber
A
19¹⁄₂" (495 mm)
B
17¹⁄₂" (444 mm)
C
15¹⁄₂" (394 mm)
D
13¹⁄₂" (343 mm)
E
11¹⁄₂" (292 mm)
Majestic Fireplaces
Black
Surround
Face
CFM164
Side of
Combustion Chamber
Ref.
Leg Depth
F
10" (254 mm)
G
8" (203 mm)
H
6" (152 mm)
I
4" (101 mm)
J
2" ( 51 mm)
Fig. 2b Combustible mantel leg minimum installation.
A hearth is not mandatory but is recommended for
aesthetic purposes. We recommend a noncombustible
CFM146

hearth.

Cold climate installation recommendation: When
installing this unit against a noninsulated
exterior wall or chase, it is mandatory
that the outer walls be insulated to
conform to applicable insulation codes.
NVC Series B-Vent
®
Mantel
Leg
Mantel
Ref.
Mantel Leg From Side
of Comb. Opening
K
12" (305 mm)
L
10" (254 mm)
M
N
O
Hearth
J
I
H
G
F
K
L
M
N
O
CFM170
8" (203 mm)
6" (152 mm)
4" (101 mm)
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nvc39Nvc43

Table of Contents