Sony RCD-W222ES Service Manual page 35

Hide thumbs Also See for RCD-W222ES:
Table of Contents

Advertisement

4.
CDM65-RBD1 Electrical Adjustment
4-1. Laser Power Adjustment
1)
Start up the TeraTermPro and set the switch S510 on the jig to "CONTROL".
2)
Select the menu as follows. Control → Macro, and select
01ldp_S.ttl.
Press "Open". (See Fig. 4-1)
3)
Press the "RESET" button (SW101) of the jig as prompted by the display.
4)
Press the "RESET" button (SW101) of the jig again as prompted by the display.
5)
When the display as shown in Fig. 4-2 appears, type the serial
number (See Fig. 4-3) that is printed on the label attached to
the RBD1. (This dialog appears only when the EEPROM IC502
is replaced.)
When the display as shown in Fig. 4-4 appears, press "No".
When the display as shown in Fig. 4-5 appears after that, press
"Yes".
4 Fig. 4-1
4 Fig. 4-2
4 Fig. 4-3
4 Fig. 4-4
4 Fig. 4-5
RCD-W222ES
35

Advertisement

Table of Contents
loading

Table of Contents