examples :
bit
7
6 5 4
3 2 1
HEX
0000 0111
07
0
0
91 1001 0001
1
1
4 Start time of read in(compression method)
bit 15 to bit 13 : (min)
0: 97 min
1: 96 min
2: 95 min
7: others
bit 12 to bit 7: (sec)
bit 6 to bit 0: (frame)
examples :
bit
15 14 13 12
HEX
0000 1101 1000 0000
0D,80
97(min)
0001 0001 0001 0110
11,16
97(min)
5 Write POWER (integer of mW x 10, available during write
processing)
examples: 00 means unavailable
(when 3 operation mode is not recording)
: A3 means 163(decimal), i.e. 16.3 mW
6 ATIME (min)/(sec)/(frame)
example: 0E, 2E, 0D means 14 : 46 : 13
Abbreviations:
ATIP : Absolute Time In Pre-groove
OPC : Optimum POWER Control
PMA : Program Memory Area
0
Operation mode
normal speed, during
standby(waiting for
command from the CD
7
system)/during search
x4 speed,
during operation of
unfinalize
1
11 10 9 8
7
6 5 4
27(sec)
34(sec)
3 2 1
0
Start time of read in
97 : 27 : 00
0(frame)
97 : 34 : 22
22(frame)