Periodic Maintenance

Twice a month, flush a white vinegar solution (one quart
vinegar to two gallons of water) or anti-browning
solution (mixed as directed) through the machine. This
will prevent build-up of alkaline residue in the system. If
spray jets become clogged, remove the spray tips,
wash them thoroughly, and blow dry.
NOTE: Do not use pins, wires, etc. to clean nozzles
as this could destroy the spray pattern.
Periodically inspect all hoses, electrical cables and
connections on your machine. Frayed or cracked hoses
should be repaired or replaced to eliminate vacuum or
solution pressure loss. The electrical cable must be
well insulated and cable connector screw kept tight. If
the cable insulation is broken or frayed, repair or
replace immediately. Don't take chances with electrical
fire or shock.

Service Schedule

Check machine for cord damage
Check recovery dome and gasket for damage and cleanliness
Check hoses for wear, blockages, or damage
Check handles, switches, and knobs for damage
Check vacuum motor intake filter and clean
Run one gallon of water through system
Clean out recovery tank and check float valve to make sure it moves freely
Clean out solution tank and remove and clean vacuum intake screen
Clean outside of all tanks and check for damage
Run vacuum motor for at least one minute to allow motor to dry
Store with dome off tank to allow the tank to dry
Check all bearings for noise
Check all gaskets for wear and leakage
Check vacuum intake screen for damage; replace if necessary
Check pump pressure; observe spray pattern and check with gauge if
necessary
Check and clean solution screen
Check cables for fraying
Check overall performance of machine
Check vacuum motor carbon brushes
86398820 Operator Manual CMPS2

Daily / Regular Maintenance

Before making any repairs or adjustments to the
machine, disconnect the power cords from the
electrical source.
Retirez le cordon d'alimentation de la machine de la
source électrique avant de procéder à des répara-
tions ou des ajustements de la machine.
1.
Empty unused cleaning solution from the solution
tank.
2. Inspect and clean filter screen in solution tank.
3. Flush pumping system with 4 to 7 liters of clean
water.
4. After each use, rinse tank with fresh water. Period-
ically inspect the recovery tank and decontaminate
if necessary, using a Hospital Grade Virucide or a
10-1 bleach to water solution. Waste water should
be disposed of properly.
5. Remove filter to clean. Filters used for wet pick-up
including striper must be thoroughly cleaned before
being allowed to dry.
6. Check spray jets for full spray pattern.
DAILY
*
*
*
*
*
*
*
*
*
*
*