Clifford 1.2 Installation Manual page 52

Remote start keyless entry
Hide thumbs Also See for 1.2:
Table of Contents

Advertisement

3-3 Crank Time 0.6
0.8 (2) 1.0 (3) 1.2 (4) 1.4 (5) 1.6 (6) 1.8 (7) 2.0 (8)
4.0 (9) SECONDS: If the unit is programmed for no engine checking or voltage
sense, the crank time must be set to the appropriate duration. The default setting
is 0.6 second and the LED will flash once. If a different crank time is desired,
toggle through the higher settings by using the two-honk settings.
3-4 Run Time 12 (1)
, 24 (2) 60 (3) MINUTES:
Selects the time in minutes
that the system will operate the engine until the system "times out". The system
may be shut down using the remote or any of the shutdowns at any time. Using
the Bitwriter®, the run time can be programmed for any duration from 1-60
minutes.
3-5 Activation Pulse One:
This allows the system to use 1 or 2 pulses to activate
the remote start sequence. The default setting is 1-pulse.
Note: This setting affects both the input wire and the remote control.
3-6 Turbo Mode:
The factory default is OFF (1). On1 min (2), On 3 min (3) On
5 min (4) On 10 min (5): In the Off setting the turbo mode does not function. In
the On and timed setting, the remote start can be used as a turbo timer. The car
remains running for the programmed runtime, and the ignition is turned Off.
3-7 Timer Mode Run Time—12min (1)
:
This is the default setting. Selects
the time in minutes that the system will operate the engine until the system "times
out" when the remote start activates in timer mode. Use the two-honk setting for
3(2), 6 (3), 9 (4) MINUTES: This is the maximum operation period and the
system may be shut down using a shutdown at any time. Using the Bitwriter®,
the run time can be programmed for any duration from 1-16 minutes.
3-8 Flex Relay Function:
Ignition 2 (1) In the factory setting, the flex relay will
function the same as the pink ignition 1 wire, in accessory setting the flex relay
will function the same as the Orange accessory 1 wire, in starter setting the flex
relay will function the same as the purple starter 1 wire.
3-9 Diesel Timer—Wait-To-Start Input
- Timed 15, 30, 45 SECONDS:
Default is the "Wait-to-Start" input control wire, or programmable to ignore the
input control wire by a delay of 15 (2), 30 (3), or 45(4) seconds. This feature
can also be optionally programmed with the Bitwriter®, with a delay from 1 to
90 seconds.
52
© 2008 Directed Electronics. All rights reserved.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents