Gas Conversions; Lp Gas Conversion - Jenn-Air JGRP430W Installation Instructions Manual

30" (76.2 cm), 36" (91.4 cm) and 48" (121.9 cm) pro-style® gas convection ranges
Hide thumbs Also See for JGRP430W:
Table of Contents

Advertisement

Available languages

Available languages

IMPORTANT: Gas conversions from Natural gas to LP gas must
be done by a qualified installer.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.

GAS CONVERSIONS

A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
1. Turn the manual shutoff valve to the closed position.
2. Unplug range or disconnect power.
To Convert Gas Pressure Regulator
1. Remove screws from kick plate.
2. Push up on kick plate to release plate from shoulder screws.
3. Gently lay kick plate aside to avoid scratching the stainless
steel.

LP Gas Conversion

WARNING
Tip Over Hazard
A
A. To range
B. Shutoff valve (closed position)
C. Gas supply line
B
A
A. Kick plate
B. Remove these screws.
B
C
13