EXCELL PRECISION CO., LTD.
Press 1 ~ 6 to select pricing units. The scale will be back to weighing & price mode.
The display will show the symbol indication "◄" for the request pricing unit.
1 ⇒ kg
2 ⇒ 100g
4 ⇒ tl.T
5 ⇒ lb
If the price unit "lb"is seleteced, the displaying will show three symbols "3".
If the price unit "oz"is selected, the displaying will not show any symbol "3".
3-4 External Weight Factory Default Setting
To Return to the factory setting, hold MC key and press CE key.
After buzzer beep sound, release two keys.
The scale will return to factory setting.
3-5 G Value Adjustment
Steps:
1.
Press 0 key and do not release, and then power on to enter int G value adjustion
mode.
2.
Press T key to search the historic G value data.
3.
Press M+ key to set and confirm G value.
4.
Press 0 ~ 9 key to input the value.
5.
Press CE key to shift the flashing digit one space to left.
6.
Press · key to exit.
It can be revise the G value in 9 times..
The G value range is from 9.78031 to 9.83217.
01007021
3 ⇒ HK catty
6 ⇒ oz
10
ZSME100000074