DRAINAGE INSTRUCTION

Switch off before carrying out any of these
operations and leave for 3 minutes before switching
on again. The extracted water is collected by the
water tank (set up as supplied), or can be set up to
drain continuously using a PVC hose (not included)
connected to a drain outlet, the drain point must
be lower than the unit outlet (see details below).
USE OF WATER TANK:
When the tank full LED illuminates the tank is full, the compressor and the
fan will stop operation, please empty the water tank. Remove the water tank
as per Fig 01 and empty it. Gently refit the water tank into the unit in its
original position. Note, if the tank full LED remains on when the tank is
emptied please remove and re-fit the tank to reset the light.
CONTINUOUS DRAINAGE
If you want to use this function, please pull out the water tank and plug a 9mm
internal diameter water pipe onto the "Water out
tube" (See Fig.02). Replace the water tank into the
unit, the unit will now operate while discharging the
extracted water through the free end of the fitted
pipe, Note, you must ensure that the free end of the
pipe is below the product outlet connection and that
the drain point is likewise lower than the unit outlet.
Filter Removal
T o remove the filter you must first remove the
water tank as instructed above.
T he filter can then be removed from its slot by
gripping the filter handle and sliding it down
and out of the back of the appliance as
indicated below.
• Every 2 weeks, remove the filter and clean it
with warm water, below 40° C. Allow it to dry
naturally and then replace by reversing the removal instruction above.