Download Print this page

Control Plate Description; Notes And Precautions; Drainage Instruction; Operation Instruction - Dimplex DXDH10N Installation And Operating Instructions Manual

10l/16l/20l

Advertisement

CONTROL PLATE DESCRIPTION

OPERATION INSTRUCTION

Starting the unit
Allow the unit to stand upright for 24hrs to let the compressor stabilize
before use.
1. Firstly, turn the humidity control switch to the "OFF" position.
2. Plug in the dehumidifier.
3. Turn on the humidity control switch (clockwise) and turn the same switch to
the reading of the desired humidity (60% in general as shown on position"4").
Turning off the unit
1. Turn the humidity control switch fully anticlockwise to the "OFF" position and
the power supply is cut off and the unit stops operating.
2. If the dehumidifier is not in use for a long time, please disconnect the power
cord plug from the supply outlet.

NOTES AND PRECAUTIONS

1. The dehumidifier will not operate if the humidity setting is higher than the
ambient humidity.
2. When the water in the tank is full an automatic float switch shuts down the
product and the water level indicator light illuminates. Remove the water
storage tank and empty its contents, carefully replace the empty water tank
back in position, the unit will now automatically restart operating.
3. When the unit stops, you have to wait for 3 minutes before you can
restart the unit to protect the compressor from damage.
4. The following table indicates the approximate relative humidity setting
3
against its related position number on the humidity control switch:
CONTROL SWITCH
POSITION NO.
8
7
6
4
2
5. The operational temperature range for this unit is 5-32°C.
6. Other than on the case of note 2 above, where the dehumidifier does not
start, the operational light does not illuminate or the dehumidifier
intermittently stops for unknown reasons, please check the plug and power
supply for poor connection. If the plug and power supply are in good
condition, wait for 10 minutes and restart the unit (it can take about 10
minutes for the unit to reset). If the unit still does not start after 10 minutes,
please contact your retailer or the manufacturer for repair.
7. When the dehumidifier is in operation, the running compressor will
produce heat. This is normal and may potentially raise the room
temperature.
8. When the product is defrosting, the defrost light will illuminate.

DRAINAGE INSTRUCTION

Switch off before carrying out any of these
operations and leave for 3 minutes before
switching on again. The extracted water is
collected by the water tank (set up as supplied),
or can be set up to drain continuously using a
PVC hose connected to a drain away outlet,
which is lower than unit outlet (see details below,
not included).
APPROXIMATE
HUMIDITY SETTING
20﹪
30﹪
40﹪
60﹪
80﹪