Wall standpipe
drain system
See requirements for floor standpipe drain system.
Floor
drain
system
(
Floor drain system requires a Siphon Break Kit (Part Number
285834), 2 Connector Kits (Part Number 285835), and an
Extension Drain Hose (Part Number 285863) that may be
purchased separately. To order, please contact the dealer from
whom you purchased your washer or an authorized service
company. Minimum siphon break: 28" (710 mm) from bottom
of washer. (Additional hoses may be needed.)
Laundry tub drain system
Minimum capacity: 20 gal. (76 L). Top of laundry tub must be at
least 39" (990 mm) above floor; install no higher than 48" (1.22 m)
from bottom of washer.
IMPORTANT: To avoid siphoning,
no more than 4.5" (114 mm)
of drain hose should be inside standpipe or below the top of
wash tub. Secure drain hose with cable tie.
ELECTRICAL REQUIREMENTS
Electrical Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow
these instructions can result in death,
fire, or electrical
shock.
CAUTION: To avoid a hazard due to inadvertent resetting of the
thermal cut off, this washer must not be supplied through an external
switching device, such as a timer, or connected to a circuit that is
regularly switched on and off by the utility.
[] A 220-240 volt, 60 Hz., AC only, 10-amp, fused electrical supply
is required. A time-delay fuse or circuit breaker is recommended.
It is recommended that a separate circuit breaker serving only this
appliance be provided.
[] This washer is equipped with a power supply cord having
a 3 prong grounding plug. If the supply cord is damaged, it
must be replaced by the manufacturer, a qualified service
agent, or other qualified person to avoid a hazard.
[] To minimize possible shock hazard, the cord must be plugged
into a mating, 3 prong, grounding-type
outlet, grounded in
accordance
with local codes and ordinances.
If a mating outlet
is not available, it is the personal responsibility
and obligation
of the customer to have the properly grounded outlet installed
by a qualified electrician.
[] If codes permit and a separate ground wire is used, it is
recommended
that a qualified electrician determine that
the ground path is adequate.
[] Do not ground to a gas pipe.
[] Check with a qualified electrician if you are not sure the
washer is properly grounded.
[] Do not have a fuse in the neutral or ground circuit.