5.3

Choice of the Location

Zone 2
Window
Recess
Zone 1
Zone 2
Zone 0
0.6 m
Window
Recess
Zone 2
Fig. A
In GB Only
Window Recess
Zone 2
Zone 1
Zone 2
Zone 0
0.6 m
Fig. B
7219717 - 02 (08/15)
Ceiling
Outside Zones
2.25 m
In GB Only
5.3.1

Location of the Appliance

Due to the high efficiency of the boiler a plume of water
vapour will be discharged from the flue. This should be
taken into account when siting the flue terminal.
1. The boiler may be fitted to any suitable wall with the flue
passing through an outside wall or roof and discharging to
atmosphere in a position permitting satisfactory removal of
combustion products and providing an adequate air supply.
The boiler should be fitted within the building unless otherwise
protected by a suitable enclosure i.e. garage or outhouse.
(The boiler may be fitted inside a cupboard).
2. If the boiler is sited in an unheated enclosure then it is
recommended to incorporate an appropriate device for frost
protection in the system controls.
3. If the boiler is fitted in a room containing a bath or shower it
MUST NOT BE fitted in zone 0 or 1, ONLY within the shaded
area (Figs. A & B shows zone dimensions for a bathtub. For
other examples refer to the Current I.E.E. Wiring Regulations)
reference must be made to the relevant requirements.
In GB this is the current I.E.E. Wiring Regulations and Building
Regulations.
In IE reference should be made to the current edition of I.S. 813
"Domestic Gas Installations" and the current ETCI rules.
4. If the boiler is to be fitted into a building of timber frame
construction then reference must be made to the current edition
of Institute of Gas Engineers Publication IGE/UP/7 (Gas
Installations in Timber Framed Housing).
5.3.2

Data Plate

1. The boiler data label gives details of the model, serial number
and Gas Council number and is situated on the lower right hand
inside face of the outercase. It is visible when the outercase
front panel is removed (Fig. 1).
5.3.3
Bath & Shower Rooms
1. If the boiler is fitted in a room containing a bath or shower it
can be fitted in zone 2, (Figs. A & B shows zone dimensions for
a bathtub. For other examples refer to the Current I.E.E. Wiring
Regulations) reference must be made to the relevant
requirements.
In GB this is the current I.E.E. Wiring Regulations and Building
Regulations.
In IE reference should be made to the current edition of I.S. 813
"Domestic Gas Installations" and the current ETCI rules.
5.3.4

Ventilation

1. Where the appliance is installed in a cupboard or
compartment, no air vents are required.
2. BS 5440: Part 2 refers to room sealed appliances installed in
compartments. The appliance will run sufficiently cool without
ventilation.