Fireplace Setup

A. Gas Log/Lighter Provision
WARNING! Fire and/or Asphyxiation Risk! Use with
solid wood fuel or decorative gas appliance only. Gas fire
generates fumes.
• DO NOT install unvented gas logs
• Damper must be locked fully open when gas logs are
installed
A certified gas log lighter or decorative gas log set can be
installed in this fireplace.
Maximum input is 100,000 BTU/hr.
Decorative gas appliance must be certified to ANSI
Z21.60 "Standard for Decorative Gas Appliances for
Installation in Vented Fireplaces".
Must be installed in accordance with the National Fuel
Gas Code, ANSI Z223.1.
A gas log set must incorporate a gas shutoff.
Gas Log set requires the damper to be locked fully open.
A listed automatic damper system with safety interlock
may be used in this fireplace with only compatible,
listed gas log sets. See damper system manufacturer's
instructions.
Knockouts are provided on both sides of the fireplace
and in refractories for 1/2 in. (13 mm) iron pipe.
Seal refractory around pipe with fireplace mortar or a
non-combustible sealant.
Firebox
Refractory
Seal with
fireplace mortar
or non-combust-
ible sealant
Gas line
Repack
insulation
knockout
(102 mm)
Figure 8.1
Gas Line Installation
VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15
Outer shell
of fireplace
Maintain air clearance
to combustibles.
Combustible
materials
1 1/2 in. (38 mm)
air space around
pipe
Gas line
Combustible materials
may be located at zero
clearance to gas line
beyond 4 in. (102 mm)
from fireplace side.
4 in.
B. Wood Burning Inserts
WARNING! Risk of Fire! Improper installation of wood in-
serts may cause fireplace or chimney system to overheat.
If a wood burning insert is being installed in this fireplace,
Vermont Castings Group recommends full reline of the
chimney.
Cooling air openings at the top of the chimney must not
be obstructed in any manner.
Vermont Castings Group recommends securing the
reline at the top of the flue and using the cap certified
for use with this fireplace system.