Technical data

Processor
RAM
ROM
User program
Screen
Keypad
Sound
Power supply
Interfaces
Operating system
File management
Technical specifications
Dimensions
Weight
Temperature
Relative humidity
Degree of protection
EMC
Safety
RF
Transmission frequency
Transmit power
Compatibility
Read/write distance to transponder
SIMATIC RF680M Mobile Reader
Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618
Intel Xscale PXA270- 624 MHz, ARM
256 MB
1 GB Flash ROM
RF680M.exe
Color Touch Display, 480 x 640 pixels, portrait
Alphanumerical
Piezo signal transmitter
Lithium-ion battery (3.7 V; 3300 mAh) for rapid
charging; automatic switch-off
LIF interface (low insertion force interface) for battery
charging and communication with PC (USB)
Microsoft Windows Embedded CE 5.0
MS-DOS-compatible
Complete unit (incl. rechargeable batteries)
265 x 100 x 42 mm
Approx. 600 g
Operation
-20 °C to +50 °C
Storage
-40 °C to +60°C (without battery)
5% to 95%, no condensation
IP65, IEC 60529 (splashproof)
EN55022; EN301489; EN55024
CSA/UL60950-1; IEC60950-1, EN60950-1
EN 300 220; FCC Part 15
EU: 865.6...867.6 MHz
USA: 902 to 928 MHz
Max. 500 mW
With all SIMATIC RF600 data carriers (tags)
Max. 250 cm
12
93