The software "RF-MANAGER"
8.3 Application mode "Mobile"
For detailed information, please refer to"EPCglobal-Specification for RFID Interface"
(EPCTM Radio-Frequency Identity Protocols Class-1 Generation-2 UHF RFID Protocol for
Communications at 860 MHz - 960 MHz, Version 1.0.9)
Displaying and executing the "Lock Tag..." function
The current status of the action bit of a tag cannot be scanned. If the specified function
cannot be executed, an error message will not be output directly from the tag. In this case,
the command will only be terminated after 20 seconds with the time-out. In this case, check
the passwords that you have entered and the bits in the mask and action lines carefully
before you activate the command again. If the status of the available tag is not known to you,
it is highly probable that this command will always result in a time-out.
8.3.5.4

Kill tag

You can erase a tag by means of the "Kill Tag..." function.
The prerequisites for this are:
● The tag must have a valid kill password (non-zero)
● The password is entered in the interface in the "Kill Password" field.
Select "Tag > Kill Tag..." for this purpose.
The following window is displayed.
Figure 8-11
48
Kill tag
Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618
SIMATIC RF680M Mobile Reader