Ems/Communication Events; Single Fault Events - Samsung RES 3.6 kWh All In One User Manual

Sdi energy storage system
Table of Contents

Advertisement

Type
WARNING
PROTECTION

7.2.7 EMS/Communication Events

Type
WARNING
WARNING
WARNING

7.2.8 Single Fault Events

Type
WARNING
Australia (Eng.) 05/2015. Rev1.1
Code
Description
E513
CELL TEMPERATURE
SENSOR 1EA
E514
CELL TEMPERATURE
SENSOR 2EA
[Table 7-7: BMS general events list]
Code
Description
E601
INVERTER
COMMUNICATION
EVENT
E602
ETHERNET EVENT
E603
ENERGY METER
EVENT
[Table 7-8: EMS/communication events list]
Code
Description
E701
GRID UNDER VOLTAGE
FAULT
E702
GRID OVER VOLTAGE
FAULT
E703
GRID UNDER
FREQUENCY FAULT
E704
GRID OVER FREQUENCY
FAULT
Message Description
Measures
Occurs above the standard battery
cell temperature.
Occurs above the standard battery
cell temperature.
Measures
Turn off and restart the system.
Reconnect the communication line
between the EMS board and the
DSP board.
Disconnect and reconnect the LAN.
Turn off and restart the Router.
Make sure that the DHCP server
function of Router is activated.
Turn off and restart the system.
Make sure that the Meter device is
properly selected.
Disconnect and reconnect the D0
cable.
Turn off and restart the system.
Measures
The operation mode is terminated
when a power system event occurs.
Restart 1 minute after the electric
power system event is settled.
The operation mode is terminated
when a power system event occurs.
Restart 1 minute after the electric
power system event is settled.
The operation mode is terminated
when a power system event occurs.
Restart 1 minute after the electric
power system event is settled.
The operation mode is terminated
when a power system event occurs.
Restart 1 minute after the electric
47