Gas Range Installation
Electrical Requirements
ELECTRICAL SHOCK HAZARD: Plug into a grounded
3-prong outlet. Do not remove ground prong. Do not
use an adapter. Failure to follow these instructions can
result in electric shock, fire or death.
The Wolf gas range requires a 110/120 V AC, 50/60 Hz
electrical supply to operate the electronic ignition system.
The service should have its own 15 amp circuit breaker. A
ground fault circuit interrupter (GFCI) is not recommended
and may cause interruption of operation.
The range is equipped with a 3-prong grounded plug.
To minimize possible shock hazard, the cord must be
plugged into a mating 3-prong grounded outlet, grounded
to conform with the National Electrical Code, ANSI/NFPA
70 latest edition, or Canadian Electrical Code (CSA) and
all local codes and ordinances. Refer to the illustration
below.
IMPORTANT NOTE: Do not ground to a gas pipe.
GROUNDED
PLUG
GROUNDED
ELECTRICAL OUTLET
Electrical ground.
WIRING DIAGRAM
The wiring diagram covering the control circuit is located
inside the lower panel of the gas range, below the oven
doors.