  • Page 1 U A L U E L A N G E S NSTALLATION NSTRUCTIONS...
  • Page 2 Another footnote we would like to identify is IMPORTANT NOTE: This highlights informa- tion that is especially relevant to a problem- free installation. ® WOLF is a registered trademark of Wolf Appliance Company, LLC...
  • Page 3: Important Note

    The proper voltage, frequency, A ventilation hood is recommended and amperage ratings are listed on the product for use with the Wolf dual fuel range. rating plate. Record the model and serial numbers before WHAT TO DO IF YOU SMELL GAS: installing the dual fuel range.
  • Page 4 Wolf dual fuel ranges are manufactured for use with natural gas or LP gas. Please A flexible gas connector, when used, must check product rating plate for type of gas not exceed 3' (.9 m).
  • Page 5 S P E C I F I C A T I O N S IMPORTANT NOTE: It is recommended that Wolf dual fuel ranges come in 30" (762), 36" you operate the Wolf dual fuel range with a (914), 48" (1219) and 60" (1524) widths.
  • Page 6 .015" (.4) stainless steel, or .024" (.6) aluminum or .02" (.5) copper. Minimum 36" (914) clearance between countertop and bottom of an unprotected wood or metal cabinet. Bottom of ventilation hood must be 30" (762) minimum to 36" (914) maximum from countertop.
  • Page 7 I N S T A L L A T I O N S P E C I F I C AT I O N S COMBUSTIBLE CONSTRUCTION VENTILATION HOOD 13" (330) 30" min (762) 30" COUNTERTOP min (762) TO 36" 18" TO COMBUSTIBLE max (914) min (457) CONSTRUCTION TO BOTTOM OF TO COUNTERTOP VENTILATION HOOD 6"...
  • Page 8 36" The island trim and min (914) COUNTERTOP 5" (127) riser may TO COMBUSTIBLE CONSTRUCTION only be used against 30" min (762) TO 18" 44" 36" min (1118) max (914) min (457) a non-combustible TO COUNTERTOP FOR CHARBROILER...
  • Page 9 5" (127) riser may only be used against 36" min (914) a non-combustible COUNTERTOP surface. TO COMBUSTIBLE CONSTRUCTION 30" min (762) TO 44" 36" 18" min (1118) max (914) min (457) FOR CHARBROILER TO BOTTOM OF TO COUNTERTOP VENTILATION HOOD 6"...
  • Page 10 5" (127) riser may only be used against 36" a non-combustible min (914) COUNTERTOP surface. TO COMBUSTIBLE CONSTRUCTION 30" min (762) TO 44" 36" 18" min (1118) max (914) min (457) FOR CHARBROILER TO BOTTOM OF TO COUNTERTOP VENTILATION HOOD 6"...
  • Page 11 I N S TA L L AT I O N I N S T R U C T I O N S U N PAC K T H E R A N G E Remove and discard all packing materials, including cardboard and tape on the outside of Do not lift the range by the oven door the range and inside the oven cavity.
  • Page 12 Carefully close the oven door to about a 60° angle from horizontal and lift the door For 30" (762) and 36" (914) ranges, the hinge away from the oven. NOTE: A slight racking pin will be inserted through the hole in the motion may be required for removal.
  • Page 13: Explosion Hazard

    I N S TA L L AT I O N I N S T R U C T I O N S G A S S U P P LY R E Q U I R E M E N T S Provide a gas supply line of "...
  • Page 14 W O L F D UA L F U E L R A N G E S G A S S U P P LY R E Q U I R E M E N T S G A S S U P P LY C O N N E C T I O N The gas pressure regulator must be checked at IMPORTANT NOTE: All connections to the gas...
  • Page 15 T H R E E - W I R E E L E C T R I C A L S Y S T E M 4.5 kW at 208V for 30" (762) and 36" (914) ranges; 10.2 kW at 240V, 8.8 kW at 208V for To connect to a three-wire electrical system, 48"...
  • Page 16 W O L F D UA L F U E L R A N G E S A N T I - T I P B R AC K E T I N S T A L L A T I O N OV E N D O O R R E I N S T A L L A T I O N IMPORTANT NOTE: The oven door(s) should...
  • Page 17 Check that the shut-off valve is in the ON position. Check operation again; if the burners do not light properly at this point, contact a Wolf authorized service center. IMPORTANT NOTE: Initial lighting of the surface burners may take slightly longer, as air in the system must be purged before gas can be supplied to the burner.
  • Page 18 T H E R A N G E IMPORTANT NOTE: Prior to operating the If removing the dual fuel range is necessary for range, be sure to read the entire Wolf Dual cleaning or service, shut off the gas supply. Fuel Ranges Use & Care Information included...
  • Page 19 Neither this book nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance Company, LLC, an affiliate of Sub-Zero Freezer Company, Inc. ©Wolf Appliance Company, LLC all rights reserved.