Important Note Wolf Gas Cooktops ......3 To ensure the safe and efficient use of Wolf equipment, please take note of the following types of highlighted Safety Instructions .
The proper voltage, frequency, and amperage ratings are listed on the product rating plate. Wolf gas cooktops are manufactured for use with natural gas or LP gas. Check the product rating plate for the type of gas for your specific model.
Follow the gas supplier’s instructions. qualified installer, service agency or the gas supplier. If you cannot reach your gas supplier, call the fire • Warranty service must be performed by a Wolf • department. authorized service center. Do not store or use gasoline or other flammable •...
Gas Cooktop Specifications wolfappliance.com/specs Gas Cooktop Dimensions 15" COOKTOP 30" COOKTOP 36" COOKTOP (381) (762) (914) 21" 21" 21" (533) (533) (533) 15" 36" 30" (762) (914) (381) 4" 4" 4" (102) (102) (102) " " " (22) (22) (22) ALL SIDES ALL SIDES ALL SIDES...
Page 6
Gas Cooktop Specifications 15" Gas Cooktop (381) INSTALLATION SIDE CABINET 30" (762) min 13" (330) COUNTERTOP TO COMBUSTIBLE 18" (457) min MATERIALS 7" 7" (178) TO (178) TO SEE COUNTERTOP " CUT-OUT BELOW COMBUSTIBLE COMBUSTIBLE (64) 4" ( 102 ) 15"...
Page 7
Gas Cooktop Specifications wolfappliance.com/specs 30" Gas Cooktop (762) INSTALLATION SIDE CABINET 30" (762) min 13" (330) COUNTERTOP TO COMBUSTIBLE 18" (457) min MATERIALS 9" 9" (229) TO (229) TO SEE COUNTERTOP " COMBUSTIBLE CUT-OUT BELOW COMBUSTIBLE (64) " 4" ( 95 ) min ( 102 ) "...
Page 8
Gas Cooktop Specifications 36" Gas Cooktop (914) INSTALLATION SIDE CABINET 30" (762) min 13" (330) COUNTERTOP TO COMBUSTIBLE 18" (457) min MATERIALS 9" 9" (229) TO (229) TO SEE COUNTERTOP " COMBUSTIBLE CUT-OUT BELOW COMBUSTIBLE (64) " 4" ( 95 ) min ( 102 ) "...
IMPORTANT NOTE: Caution must be used in planning the you the total countertop cut-out width. Dimensions proper installation of the Wolf gas cooktop to avoid fires or include the filler strip available through your authorized damage to adjacent cabinetry or kitchen equipment.
Page 10
Refer to the illustration below. designed for one gas to be operated with the other gas. Wolf natural gas cooktops will function up to an altitude Such conversions must be performed by a Wolf authorized of 10,250' (3124 m) without any adjustment.
Page 11
Gas Supply Pressure: The maximum gas supply pressure to the regulator should never exceed 14" The Wolf gas cooktop requires a 120 V AC, 60 Hz electri- (34.9 mb) WC; .5 psi (3.5 kPa) for natural and LP gas. cal supply to operate the electronic ignition system. The The minimum line pressure is 7"...
Gas Cooktop Installation Wiring Diagram Model CT15G LR SPARK RR SPARK MODULE MODULE 3 CONDUCTOR POWER CORD WHITE WHITE BLACK WHITE WHITE LF SPARK RF SPARK MODULE MODULE WHITE WHITE LEFT RIGHT REAR REAR WHITE WHITE Model CT30G LEFT RIGHT FRONT FRONT LR SPARK...
Page 13
Gas Cooktop Installation wolfappliance.com/specs Install the Cooktop Remove the cooktop, gas pressure regulator, burner GAS PRESSURE REGULATOR grates and burner caps from the shipping package. Install the gas pressure regulator with the arrow on the Lower the cooktop into the countertop cut-out opening. regulator pointing up toward the unit and in a position Center the cooktop in the opening and check that the where you can reach the access cap.
Page 14
If a leak appears, shut off the gas supply and adjust minutes; if the burners do not light properly, contact a connections. Then check connections again. Clean the Wolf authorized service center. detergent solution from the cooktop. IMPORTANT NOTE: Initial lighting of the surface burners may take slightly longer, as air in the system must be purged before gas can be supplied to the burner.