Electrical Wiring - Nordyne SC Series Installation Instructions Manual

Single stage condensing gas furnaces
Hide thumbs Also See for SC Series:
Table of Contents

Advertisement

WARNING:
Conversion to LP / Propane is detailed in the installation
instructions provided with the conversion kit. Generally,
this will require the replacement of the burner orifices and
the spring found under the cap screw on the pressure
regulator. Approved conversion kits are listed below:
Installations in the United States: For Propane (LP)
conversion or for LP gas installations in altitudes between
2,000 ft. and 10,000 ft. above sea level, use the LP &
High Altitude LP Gas Conversion Kit (P/N 904914) for
Installations in the United States.
Installations in Canada: For Propane (LP) conversion or
for LP Gas installations in altitudes between zero and
4,500 ft. above sea level, use the LP & High Altitude
LP Gas Conversion Kit (P/N 904915) for Installations
in Canada.
If the installation is in the U.S. and above 2,000 ft., refer
to
Table 12 (page 41)
to determine the correct orifice
size and regulator pressure. See example below.
When conversion is complete, verify the manifold pressure
and input rate are correct as listed in the table.
Elevation:............................................5,000 feet
Type of Gas: .......................................Propane Gas
Input BTUH of Furnace:......................72,000
From
Table
12, find 5,000 and follow across the row,
stop at the 72,000 btu column. The manifold pressure
listed is 10.0 and the orifice size is 57.
HAZARD
.
applicable local codes with the current revision of the
National Electric Code (ANSI/NFPA 70).
and grounding shall comply with the current Canadian
Electrical Code (CSA C22.1 and/or local codes).