Internal Controls

On-board Pushbuttons
Seven pushbuttons are on the main circuit board. Refer to the fi gure for
the location of each pushbutton.
• "UP" BUTTON adds one to the value on the STATUS/PROGRAM display.
• "DOWN" BUTTON subtracts one from value on the STATUS/PROGRAM
display.
• RELAY "A" LATCH press to latch relay "A", press again to un-latch.
• RELAY "B" LATCH press to latch relay "B", press again to un-latch.
• RELAY "C" LATCH press to latch relay "C", press again to un-latch.
• RELAY "D" LATCH press to latch relay "D", press again to un-latch.
• ENTER BUTTON press to accept the value on the STATUS/PROGRAM
display during programming, press to clear an indication during the
supervisory display.
On-board Display
The STATUS/PROGRAM display will show system conditions and can be
used to aid system setup.
Status Mode
While the system is running, the display will show the current system
status. Normally the left digit will show a moving pattern and the right digit
will show the unit's Network Node number.
When a supervisory condition exists, the display will cycle to show the
condition(s). When an item is displayed, press the ENTER button to clear
the display (clears the display only, the condition may still exist). Refer to
the following table for the supervisory condition display codes.
STATUS MODE DISPLAY
DISPLAY
01
MGT TRANSMITTER STATUS EXCEPTION
02
MGT TRANSMITTER LOW BATTERY
03
MGT TRANSMITTER TAMPER
04
AC POWER FAIL (BACKUP BATTERY REQUIRED)
05
CHANNEL "A" LOCKED CLOSED
06
CHANNEL "B" LOCKED CLOSED
07
CHANNEL "C" LOCKED CLOSED
08
CHANNEL "D" LOCKED CLOSED
Program Mode
Options for up to ten system settings can be controlled in Program Mode.
By viewing the STATUS/PROGRAM display and using the UP, DOWN,
and ENTER pushbuttons, the various options can be set for each of the
system settings.
Refer to the following steps to change the system settings:
1. To enter Program Mode, press and hold the UP and DOWN
pushbuttons for one second.
2. The display will alternate between the system setting number and
the option value currently set for it. When showing the system
setting number, the left digit of the display will show the system
setting number (0-9) and the right digit of the display will be blank.
When showing the option value both display digits are used to
show the 2-digit option value.
3. Press the ENTER button while the system setting number is
displayed to advance the system setting number.
4. Press the UP or DOWN button while the option value is displayed
to change the option value.
✦ NOTE: A unique network address (1-8) must be set before
communicating with network. The master node must be set to 1
(default).
CONDITION
STATUS/PROGRAM
DISPLAY
"ENTER"
BUTTON
AE-1000 MAIN
CIRCUIT BOARD
SYSTEM IDLE
RIGHT DIGIT SHOWS NETWORK NODE ADDRESS
LEFT DIGIT CIRCULATES
STATUS MODE
DIGITS SHOW SUPERVISORY CODE
PROGRAM MODE
DISPLAY ALTERNATES
RIGHT DIGIT BLANK
DIGITS SHOW THE OPTION VALUE
LEFT DIGIT SHOWS THE SYSTEM SETTING NUMBER
PROGRAM MODE DISPLAY
SYSTEM SETTING NUMBER
0
"UP"
BUTTON
"DOWN"
BUTTON
RELAY "A"
LATCH
RELAY "B"
LATCH
RELAY "C"
LATCH
RELAY "D"
LATCH
STATUS/PROGRAM
DISPLAY
VALID OPTION VALUES
NETWORK NODE ADDRESS 01-08