TO CORD ASSEMBLY 110V
BATTERY PACK
Figure 10.2 IPI Wiring Diagram
THERMOCOUPLE
VALVE
Figure 10.3 Standing Pilot Ignition Wiring Diagram
IGNITION MODULE 3 VAC
TRANSFORMER
3 VAC
REMOTE WIRE
ASSEMBLY
PILOT ASSEMBLY
THERMOPILE
PIEZO
RED
WHT
Heatilator • NDI30-C, NDI30-SP, NDI35-C, NDI35-SP • 2226-901 Rev. S • 6/15
INTERMITTENT PILOT IGNITOR
I
S
ORG
WHT
GROUND TO
FIREPLACE
CHASSIS
VALVE
WALL SWITCH OR
REMOTE CONTROL
NOTE: 1/4 IN. FEMALE SPADE
CONNECTORS CONNECT TO
THE REMOTE WIRE ASSEMBLY
ON
OFF
ON/OFF
SWITCH
OPTIONAL WALL SWITCH,
ROCKER
THERMOSTAT OR REMOTE
SWITCH