Milli-Volt Control Lighting Instructions - Monessen Hearth VWF18 Installation And Operating Instructions Manual

Vented gas log set
Table of Contents

Advertisement

MILLI-VOLT CONTROL LIGHTING INSTRUCTIONS

MILLI-VOLT CONTROL LIGHTING INSTRUCTIONS
1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. Turn gas control knob clockwise
"OFF" position.
4. Wait (5) minutes to clear out any gas. Then smell for gas, including near the fl oor. If you smell
gas, STOP!
5. From "OFF" position, turn the gas control knob counterclockwise
Push in control knob for 5 seconds.
6. With the control knob pushed in, light pilot with match.
7. Continue pushing the control knob in for a further 60 seconds to prevent the fl ame detector from
shutting off the gas while the probe is warming up. Release the control knob.
8. Turn gas control knob counterclockwise
9. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF
switch to "ON" position.
10. If the gas logs will not operate, follow the instructions "To Turn Off Gas to Heater" and call your
service technician or gas supplier.
Figure 30 - Pilot
1. Turn control knob clockwise
2. If applicable: Turn ON/OFF switch to OFF position.
27D8520
O N
Figure 31 - Control Knob
TO TURN OFF GAS TO HEATER
to OFF position to completely shut off the heater.
OPERATING INSTRUCTIONS
to the "OFF" position, and turn ON/OFF switch to
to the "ON" position.
O F
F
to "PILOT" position.
Figure 32 - On/Off Switch