OPERATING INSTRUCTIONS
MILLI-VOLT CONTROL LIGHTING INSTRUCTIONS
1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo
ignitor does not light the pilot, refer to instructions for Match Lighting Instructions, page 33.
4. Turn gas control knob clockwise
5. Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP!
Follow the instructions under What To Do If You Smell Gas, page 31.
6. From OFF position, turn the gas control knob counterclockwise
control knob for 5 seconds. NOTE: If you are running the heater for the fi rst time, it may be
necessary to press in the control knob for 30 seconds or longer to allow air to bleed out
of the gas piping.
7. With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
8. Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shutting
off the gas while the probe is warming up. Release the control knob.
9. Turn gas control knob counterclockwise
10. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to ON
position.
11. If the gas logs will not operate, follow the instructions To Turn Off Gas To Heater below and call your
service technician or gas supplier.
Figure 37 - Pilot
1. Turn control knob clockwise
2. If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
3. If applicable: Turn off all electric power to the heater.
32
to the OFF position and turn ON/OFF switch to OFF position.
Piezo
Ignitor
Figure 38 - Controls
TO TURN OFF GAS TO HEATER
to OFF position to completely shut off the heater.
to the ON position.
Switch
to IGN position. Push in
Pilot
Hi/Lo Knob
On/Off/Pilot
Knob
70D0004