Manual Control Lighting Instructions - Monessen Hearth DLX18 Installation And Operating Instructions Manual

Unvented gas log heater or vented decorative appliance
Table of Contents

Advertisement

MANUAL CONTROL LIGHTING INSTRUCTIONS

1.
STOP! Read the safety information.
2.
Make sure the manual shutoff valve is fully open.
3.
This heater is equipped with an ignition device (piezo) which automatically lights the pilot.
4.
See Figure 27, page 26 for the location of the piezo ignitor and control knob. Push in gas control knob
slightly and turn control knob clockwise to the OFF position.
NOTE: Knob cannot be turned to OFF unless knob is pushed in slightly. Do not force.
5.
Wait 5 minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas STOP!
Follow the instructions under
step.
6.
From OFF position, push in gas control knob slightly and turn counterclockwise
position. See Figure 29. Push in and hold control knob for 5 seconds.
NOTE: If you are running the heater for the first time, it will be necessary to press in the control knob
for 30 seconds to allow air to bleed out of the gas piping.
7.
With the control knob pushed in, push and release the piezo ignitor button to light the ODS pilot. The
pilot is located on the right side of the heater, behind the front log and in front of the main burner. If
piezo ignitor does not light the pilot, See
8.
Hold the control knob in for an additional 10 seconds to prevent the ODS pilot from shutting off the gas
while the thermocouple is warming up.
9.
Release the control knob.
• If the knob does not pop out when released, stop and immediately call your service technician or gas
supplier.
• If the ODS pilot will not stay lit after several tries, push and turn the gas control knob clockwise
to OFF and wait 15 seconds. Repeat steps 6 through 9.
10. Push in control knob and turn to desired setting (LOW or HIGH). The control knob must be set at either
the low or high position, and the control knob will pop out when positioned correctly. Do not set the
control knob at a position between LOW and HIGH. See Figures 30 and 31.
Push
Figure 29 - IGN Position
1. Turn control knob clockwise
2. If applicable: Turn off all electric power to the heater.
14D9999
What to Do if you Smell Gas, page 26
Rotate
Rotate
Push
Figure 30 - HIGH Position
TO TURN OFF GAS TO HEATER
to OFF position to completely shut off the heater.
Match Lighting Instructions
OPERATING INSTRUCTIONS
. If you do not smell gas, go to the next
, page 30.
Push
Figure 31 - LOW Position
to the IGN
Rotate
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dlx24Dlx28

Table of Contents