36
5.3
MINIMUM ENCLOSURE CLEARANCES
THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS
SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT COVER
THE STEEL STUD FRAMING KITS WITH CEMENT BOARD PROVIDED, MUST BE INSTALLED.
5.3.1 GD36
COMBUSTIBLE
3
9
/
" MINIMUM
4
42
1
/
"
4
REAR EXIT ENCLOSURE
The appliance requires a minimum enclosure height
of 42 1/4". For temperature requirements, the enclo-
sure space around and above the appliance must
be left unobstructed.
* See "VENTING" section.
W415-0773 / 06.16.09
THE APPLIANCE OPENING.
NON-COMBUSTIBLE
BRICK
0" IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
2"
AND STONE.
1"
24" MINIMUM
PLUS RISE*
2"
WARNING
!
RISK OF FIRE!
COMBUSTIBLE
2" MINIMUM
30"
1
1
/
"
2
63"
TOP EXIT ENCLOSURE
The appliance requires a minimum enclosure height
of 63". For temperature requirements, the enclosure
space around and above the appliance must be left
unobstructed.
NON-COMBUSTIBLE
BRICK
0" IF
2"
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
1"
57" MINIMUM
PLUS RISE*
2"