Software Components - HP StoreEasy 1000 Storage Administrator's Manual

Hide thumbs Also See for StoreEasy 1000 Storage:
Table of Contents

Advertisement

Table 1 Systems Insight Display LEDs and internal health LED combinations (continued)
Systems Insight
Display LED and
color
Over temp (amber)
PCI riser (amber)
Fan (amber)
Power supply
(amber)
Power cap (off)
Power cap (green)
NOTE:
For more information on troubleshooting, refer to the hardware platform information. The
following list identifies the ProLiant model for each HP StoreEasy 1000 Storage product:
1440: ProLiant DL360e Gen8
1550: ProLiant ML310e Gen8 v2
1640: ProLiant DL380e Gen8
1840: ProLiant DL380p Gen8
The ProLiant documentation is available at:
http://www.hp.com/go/proliantgen8/docs

Software components

Windows Storage Server 2012 or 2012 R2 Standard Edition comes preinstalled and activated
on the HP StoreEasy 1x30 Storage. Windows Storage Server 2012 R2 Standard Edition comes
preinstalled and activated on the HP StoreEasy 1x40 Storage. The storage system configuration
also includes the HP Initial Configuration Tasks window, Windows Server Manager, and HP
StoreEasy tools, which are used to set up and manage your storage system.
18
HP StoreEasy 1000 Storage
Health LED
System power LED
Amber
Green
Amber
Green
Red
Amber
Red
Green
Amber
Green
Red
Green
Red
Amber
Amber
Green
Amber
Flashing green
Green
Status
DIMM in slot X is in a pre-failure condition.
The Health Driver has detected a cautionary temperature
level.
The server has detected a hardware critical temperature
level.
The PCI riser cage is not seated properly.
One fan has failed or is removed.
Two or more fans have failed or are removed.
One or more of the following conditions may exist:
Only one power supply is installed and that power
supply is in standby.
Power supply fault
System board fault
One or more of the following conditions may exist:
Redundant power supply is installed and only one
power supply is functional.
AC power cord is not plugged into redundant power
supply.
Redundant power supply fault
Power supply mismatch at POST or power supply
mismatch through hot-plug addition
Standby
Waiting for power
Power is available.

Hide quick links: