F-45
AUXILIARY TRANSFORMER NO. 1 TEST (CONTINUED)
LEAD IDENTIFICATION
7. Carefully apply the correct input voltage to
the Power Wave 455/R.
8. Check for the correct secondary voltages
according to Table F.7.
NOTE: The secondary voltages will vary if the
input line voltage varies.
TROUBLESHOOTING & REPAIR
TABLE F.7 – SECONDARY VOLTAGES
X1 to X2
X3 to X5
X3 to X4
WARNING
ELECTRIC SHOCK can kill.
High voltage is present at prima-
ry of the Auxiliary Transformer.
POWER WAVE 455/R
NORMAL EXPECTED VOLTAGE
52 VAC
115 VAC
24 VAC
9. If the correct secondary voltages are pre-
sent, the T1 auxiliary transformer is func-
tioning properly. If any of the secondary
voltages are missing or low, check to make
certain the primary is configured correctly
for the input voltage applied.
Wiring Diagram.
10. If the correct input voltage is applied to the
primary, and the secondary voltage(s) are
not correct, the T1 transformer may be
faulty.
11. Replace any cables ties and insulation
removed earlier.
12. Install the case sides and top using the 3/8"
nut driver.