Troubleshooting Guide - Lincoln Electric POWER WAVE SVM156-A Service Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

F-4
Observe Safety Guidelines
detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
Major physical or electrical damage
is evident when the sheet metal
covers are removed.
The input fuses repeatedly fail or
the input circuit breakers keep trip-
ping.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely,
contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
1-800-833-9353.
TROUBLESHOOTING & REPAIR
POSSIBLE AREAS OF
MISADJUSTMENT(S)
OUTPUT PROBLEMS
Contact your local authorized
Lincoln
Electric
Facility for technical assistance.
1. Make certain the fuses or break-
ers are properly sized.
2. Make certain the reconnect
panel is configured properly for
the applied voltage.
3. The welding procedure may be
drawing too much input current
or the duty cycle may be too
high. Reduce the welding cur-
rent and /or reduce the duty
cycle.
CAUTION
POWER WAVE 455/R

TROUBLESHOOTING GUIDE

RECOMMENDED
COURSE OF ACTION
Contact the Lincoln Electric Service
Field
Service
Department at 1-800-833-9353
(WELD).
1. Check the reconnect switches
and associated wiring. See the
Wiring Diagram.
2. Perform the Input Rectifier
Test.
3. Perform the Switch Board Test.
4. Perform the Input Contactor
Test.
F-4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power wave 455/r

Table of Contents