Electrostatic Discharge (Esd) Precautions Procedure; Introduction; Dimensional Drawing - Carrier 58UHV Installation, Start-Up, And Operating Instructions Manual

Upflow/horizontal variable-speed, 2-stage induced-combustion gas furnaces sizes 060-120, series 110 and 120
Table of Contents

Advertisement

28
VENT CONN
7
-IN. DIA HOLE
8
POWER ENTRY
7
-IN. DIA
8
ACCESSORY
3
1
-IN. DIA HOLE
4
39
7
8
GAS ENTRY
1
-IN. DIA HOLE
2
THERMOSTAT
WIRE ENTRY
SIDE INLET (FOR UPFLOW
INSTALLATION ONLY)
5
24
11
16
AIR INLET
DIMPLES TO DRILL HOLES FOR HANGER BOLTS:
8 PLACES (FOR HORIZONTAL INSTALLATIONS ONLY)
NOTES:
1. Two additional
2. Minimum return-air openings at furnace, based on metal duct. If flex duct is used,
see flex duct manufacturer's recommendations for equivalent diameters.
a. For 800 CFM–16-in. round or 14
b. For 1200 CFM–20-in. round or 14
c. For 1600 CFM–22-in. round or 14
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific
use of single side inlets. The use of both side inlets, a combination of 1 side and the bottom, or the
bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.
UNIT SIZE
060-12
080-16
100-20
120-20
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS
PROCEDURE
Electrostatic discharge can affect electronic components.
Take precautions during furnace installation and servicing to
protect the furnace electronic control. Precautions will pre-
vent electrostatic discharges from personnel and hand tools
which are held during the procedure. These precautions will
help to avoid exposing the control to electrostatic discharge
by putting the furnace, the control, and the person at the same
electrostatic potential.
1. Disconnect all power to the furnace. DO NOT TOUCH THE
CONTROL OR ANY WIRE CONNECTED TO THE CON-
TROL PRIOR TO DISCHARGING YOUR BODY'S ELEC-
TROSTATIC CHARGE TO GROUND.
2. Firmly touch a clean, unpainted, metal surface of the furnace
chassis which is close to the control. Tools held in a person's
hand during grounding will be satisfactorily discharged.
3. After touching the chassis you may proceed to service the
control or connecting wires as long as you do nothing that
recharges your body with static electricity (For example: DO
NOT move or shuffle your feet, DO NOT touch ungrounded
objects, etc.).
1
2
1
2
16
1†
3
5
8
5
12
16
13
5
16
3
2
8
3†
16
11
16
7
-in. dia holes are located in the top plate.
8
1
2
1
1
Fig. 1—Dimensional Drawing
Table 1—Dimensions (In.)
A
D
14-3/16
12-9/16
21
19-3/8
24-1/2
22-7/8
24-1/2
22-7/8
A
D
5
2
11
E
x 12-in. rectangle.
1
x 19
-in. rectangle.
2
2
1
x 23
-in. rectangle.
2
4
E
12-11/16
19-1/2
23
23
4. If you touch ungrounded objects (recharge your body with
static electricity), firmly touch furnace again before touching
control or wires.
5. Use this procedure for installed and uninstalled (ungrounded)
furnaces.
6. Before removing a new control from its container, discharge
your body's electrostatic charge to ground to protect the
control from damage. If the control is to be installed in a
furnace, follow items 1 through 5 before bringing the control
or yourself into contact with the furnace. Put all used AND
new controls into containers before touching ungrounded
objects.
7. An ESD service kit (available from commercial sources) may
also be used to prevent ESD damage.
The models 58UHV and 58UXV Series 110 or 120 Furnaces are
available in sizes 60,000 through 117,000 Btuh input capacities.
These furnaces use variable-speed motors manufactured by Gen-
eral Electric (GE) and known as ICM2+ motors. They are
integrated control motors, which include a pre-programmed micro-
processor-based control to precisely control the selected airflow
rates. The motor will be referred to as ICM2+ in the rest of this
document.
2
1
2
16
19†
13
16
OUTLET
1†
7
-IN. DIA
8
POWER ENTRY
3
5
8
1
1
-IN. DIA
11
2
2
16
13
R.H. GAS ENTRY
16
3
8
7
-IN. DIA ACCESSORY
8
1
-IN. DIA THERMOSTAT
2
WIRE ENTRY
SIDE INLET (FOR UPFLOW
INSTALLATION ONLY)
TYP 1 †
16
5
8
1
23
TYP
SIDE RETURN
DUCT LOCATION
AIRFLOW
FLUE COLLAR
4
4
4
5

INTRODUCTION

13
16
1
14
2
3
1
4
1†
4
A99274
SHIP. WT
132
156
183
194

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

58uxv58uxv series58uhv series

Table of Contents