58UVB PERFORMANCE
95% AFUE UPFLOW ONLY VARIABLE---SPEED
CONDENSING GAS FURNACE
Series 120, Input Rates 60,000 thru 120,000 Btuh
Comfort Heatt TECHNOLOGY,
THE ULTIMATE IN HEATING
COMFORT...
The Carrier Performancet 96 with Comfort Heatt technology
achieves the optimum combination of comfort and efficiency.
The Performancet 96 achieves up to 95 percent Annual Fuel
Utilization Efficiency (AFUE). Efficient performance is enhanced
through the variable- -speed design. To maintain ideal comfort,
Comfort Heat technology automatically adjusts the heating level,
maximizing the use of low heating levels that produce near silent
furnace operation while meeting the exact heating needs. This
unit is designed to keep the indoor temperature within 1 degree of
the thermostat set point. Because it operates in low heat most of
the time, the Performance 96 uses up to 80% less power than
single- -capacity furnaces.
96
t
Product Data
In addition to providing ultimate comfort, the Performance 96 has
a sealed combustion system. This system brings combustion air to
the furnace and vents flue gases outside the furnace in a safe
manner. Because it is sealed, operational noise is minimal. A
sealed combustion system also means fewer cold drafts and less
air infiltration.
The Performance 96 is available in 5 heat/airflow combinations.
The unit has an upflow only design. The Performance 96 can be
installed as a Direct vent/2- -pipe only. The Performance 96 is not
approved for installation in mobile homes, recreational vehicles,
or outdoor use.
The variable speed makes the Performance 96 ideal for use with
split- -system cooling, including 2- -stage units. A Carrier
electronic air cleaner, humidifier, Thermidistatt, comfort
ventilator, and Comfort Zonet II will provide year- -round
comfort and efficiency.
Designed for durability, comfort, and reliability, the Performance
96 is the ultimate in versatile, efficient comfort.
IdealHumidity Technology
The IdealHumidity system actively controls both temperature and
humidity in your home to provide the best comfort all year long.
Other systems depend on heating or cooling to manage the
A05097
moisture in the air. But IdealHumidity gives you the right amount
of humidity, day and night, even in mild weather. No other
manufacturer can do this! IdealHumidity saves energy, too. By
keeping humidity under control, you can set your thermostat to
stay comfortable and save energy—up to 20% off your cooling
costs!
Comfort Heat Technology
On the coldest days of the year, the Performance 96 Furnace has
the capacity to heat your home. On moderate days when less heat
is required, this furnace will regulate itself to a lower
capacity—providing a comfortable home and minimizing
operating costs.
The patented algorithm adjusts the low- -heat operating time to
match the indoor conditions.
Reliable Heat Exchanger Design
The primary heat exchanger is made of aluminized steel for
corrosion resistance. The patented Serpentufft condensing heat
exchanger cells are laminated with polypropylene for greater
resistance to corrosion and epoxy coated externally to prevent
oxidation. This breakthrough in heating technology helps extend
the life of the furnace for years of dependable performance. The
heat exchanger is positioned in the furnace to extract additional
heat.
1
PERFORMANCE 96 FEATURES/
BENEFITS

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 58UVB PERFORMANCEt 96

  • Page 1 The variable speed makes the Performance 96 ideal for use with split- -system cooling, including 2- -stage units. A Carrier electronic air cleaner, humidifier, Thermidistatt, comfort ventilator, and Comfort Zonet II will provide year- -round comfort and efficiency.
  • Page 2 Power Heatt Igniter Electronic Variable- -Speed Motors Carrier’s unique SiN igniter is not only physically robust but it is ECM Motors (Electronically Commutated Motor) provide also electrically robust. It is capable of running at line voltage and variable- -speed operation to optimize comfort levels in the home does not require complex voltage regulators as do other brands.
  • Page 3 A02287 NOTES: 1. The 58UVB Furnace is built for use with natural gas. The furnace can be converted for propane gas with a factory ---authorized and listed accessory conver- sion kit. 2. Control location and actual controls may be different than shown above. 1.
  • Page 4: Model Number Nomenclature

    Condensing Gas Furnace Input Rates 060 --- 60,000 Btuh 080 --- 80,000 Btuh 100 --- 100,000 Btuh 120 --- 120,000 Btuh CARRIER ACCESSORIES UNIT SIZE DESCRIPTION PART NO. 060--- 14 080--- 14 080--- 20 100--- 20 120--- 20 2--- in. — KGAVT0101BRA Vent Termination Kit (Bracket Only for 2 Pipes) 3--- in.
  • Page 5 CARRIER ACCESSORIES CONTINUED UNIT SIZE DESCRIPTION PART NO. 060--- 14 080--- 14 080--- 20 100--- 20 120--- 20 Natural--- To--- Propane Gas Conversion Kit (Single Kit)* KGANP4601ALL Propane--- To--- Natural Gas Conversion Kit (Single Kit) KGAPN3901ALL ECM Motor Simulator (simulates the ECM blower and inducer...
  • Page 6 THERMOSTAT AND ZONING CONTROL OPTIONS NON---PROGRAMMABLE THERMOSTAT SELECTION For use with 1 speed Air Conditioner --- _F/_C, Auto Changeover TC ---NAC or TP ---NAC TC ---NHC or TP ---NHC For use with 1 speed Air Conditioner --- _F/_C, Auto Changeover TP ---NRH* For use with 2 speed Air Conditioner --- _F/_C, Auto Changeover * Model HP &...
  • Page 7 FACTORY TEST CONTINUOUS FAN CONNECTOR (CF) AIRFLOW MODEL PLUG SETUP SWITCHES CONNECTOR SW1 SETUP SWITCHES AND BLOWER OFF- DELAY AIR CONDITIONING (A/C) AIRFLOW SETUP SWITCHES HUMIDIFIER TERMINAL (24-VAC 0.5 AMP MAX. ACRDJ AIR CONDITIONING RELAY DISABLE JUMPER 24-V THERMOSTAT TERMINALS STATUS AND COMM LED LIGHTS PL3 ECM BLOWER...
  • Page 8 Energy recovery ventilator is Moisturizing household For the ultimate in home shown. air also helps to retain comfort, Carrier’s 2- -, 4- -, normal body heat and or 8- -zone systems allow provides comfort at lower temperature control of temperature.
  • Page 9: Physical Data

    PHYSICAL DATA UNIT SIZE DESCRIPTION 060--- 14 080--- 14 080--- 20 100--- 20 120--- 20 Direct--- Drive Motor Hp (ECM) Motor Full Load Amps 12.8 12.8 12.8 RPM (Nominal)—Speeds Variable 250 — 1300 Blower Wheel Diameter X Width (in.) 10 X 7 11 X 10 11 X 10 11 X 10...
  • Page 10 AIR DELIVERY - - CFM (BOTTOM RETURN WITH FILTER)* External Static Pressure (ESP) In. W.C. CFM Airflow External Static Unit Size Operating Mode Setting Pressure Range* 060 ---14 †† Low Heat 635† 0 ---0.50 High Heat 1070† 0 ---1.0 1070 1070 1070 1070...
  • Page 11: Condensate Trap

    CONCENTRIC VENT (DIRECT VENT/2- -PIPE ONLY) (ALL MODEL SIZES) B IN. DIA PVC VENT/EXHAUST C IN. DIA 1 /2 B IN. DIA PVC INTAKE/COMBUSTION AIR A97110 Dimensions (In / mm) KIT PART NO. KGAVT0701CVT 33--- 3/8 (847.7) 2 (50.8) 3--- 1/2 (88.9) 16--- 5/8 (422.3) 6--- 1/4 (158.8) 5--- 3/4 (146.1)
  • Page 12: Electrical Data

    DIMENSIONS A09680 Dimensions - - In. (mm) UNIT SIZE 060--- 14 17--- 1/2 (445) 15--- 7/8 (403) 16 (406) 080--- 14 21 (533) 19--- 3/8 (492) 19--- 1/2 (495) 080--- 20 21 (533) 19--- 3/8 (492) 19--- 1/2 (495) 100--- 20 21 (533) 19--- 3/8 (492) 19--- 1/2 (495)
  • Page 13: Typical Wiring Schematic

    TYPICAL WIRING SCHEMATIC FIELD 24-VOLT WIRING FIELD 115-, 208/230-, 460-VOLT WIRING FACTORY 24-VOLT WIRING FACTORY 115-VOLT WIRING NOTE 2 1-STAGE THERMOSTAT FIVE FIELD-SUPPLIED TERMINALS WIRE FUSED DISCONNECT THREE-WIRE 208/230- OR HEATING- 460-VOLT ONLY THREE PHASE 208/230- W/W1 VOLT NOTE 1 SINGLE Y/Y2 115-VOLT FIELD-...
  • Page 14 MAXIMUM ALLOWABLE PIPE LENGTH (FT / M) Direct Vent (2 ---Pipe Only) NUMBER OF 90_ ELBOWS UNIT SIZE Termination Pipe Dia ALTITUDE (BTUH) Type (IN.)* 2 Pipe or 2--- In. 1--- 1/2 50 / 15.2 45 / 13.7 40 / 12.9 35 / 10.7 30 / 9.1 25 / 7.6...
  • Page 15 MAXIMUM ALLOWABLE PIPE LENGTH (FT / M) (CONTINUED) Direct Vent (2- -Pipe Only) NUMBER OF 90_ ELBOWS UNIT SIZE ALTITUDE Termination Pipe Dia (BTUH) Type (IN.)* 2 Pipe or 2--- In. 1--- 1/2 35 / 10.7 30 / 9.1 25 / 7.6 20 / 6.1 15 / 4.6 10 / 3.0...
  • Page 16: Clearance To Combustibles

    MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH - - FT (M) WITH INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT* MAXIMUM PIPE INSULATION THICKNESS† WINTER DESIGN UNIT SIZE DIAMETER DIAMETER TEMPERATURE IN. (MM) 20_F / --- 6.7_C 2 (51) 30 (9.1) 55 (16.8) 61 (18.6) 70 (21.3) 70 (21.3)
  • Page 17: Typical Installations

    TYPICAL INSTALLATIONS COMBUSTION AIR PIPE OUTDOOR UNIT VENT PIPE A/C COIL HUMIDIFIER GAS-FIRED ELECTRONIC WATER HEATER AIR CLEANER FRONT OF AIRFLOW FURNACE A06511...
  • Page 18 Refer to section of the product data identifying accessories and descriptions for specific features and available enhancements. Copyright 2010 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition date: 09/10 Catalog No:58UVB---2PD Replaces: 58UVB- -1PD Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Table of Contents