WELD MODES

ELECTRODE AND GAS
Ar
ALUMINUM 4043
ALUMINUM 4043
Ar
ALUMINUM 5356
Ar
ALUMINUM 5356
Ar
WAVEFORM CONTROL TECHNOLOGY
72
IR PORT
4043 Pulse Ar
WELD MODE
ARC CONTROL
ARC CONTROL
PULSE
DESCRIPTION
FREQUENCY:
(Low)-10.0 to
For Pulse modes, Arc Control
(High)+10.0
changes the pulsing frequency.
When the frequency changes,
the Power Wave system auto-
matically adjusts the back-
ground current to maintain a
similar heat input into the weld.
Low frequencies give more con-
trol over the puddle and high
frequencies minimize spatter.
PULSE-ON-PULSE
For Pulse -On-Pulse modes,
FREQ.MODULATION
Arc controls changes the frequ-
ency modulation. The freque-
(Low)-10.0 to
-ncy modulation controls the
(High)+10.0
spacing of the ripples in the
weld. Use low values for slow
travel speeds and wide welds,
and high values for fast travel
speeds and narrower welds.
220
WFS
AMPS
Less
More
Deposition
Deposition
WIRE SIZE
0.035 3/64 1/16
149
72
74
98
99 100
152
76
78
101 102 103
Aluminum
3/64"
SETUP
START OPTIONS
END OPTIONS
SET
1.06
VOLTS
TRIM
Shorter
Longer
Arc
Arc
START OPTIONS
PREFLOW TIME
0 - 10 seconds
Adjusts the time that shielding
gas flows after the trigger is
pulled and prior to feeding wire.
RUN-IN WFS:
Off, 50 to150 in/min.
Run-in sets the wire feed
speed from the time the trigger
is pulled until an arc is estab-
lished.
Start Procedure
The Start Procedure controls
the WFS. Trim at a specified
time at the beginning of the
weld. During the start time, the
machine will ramp up or down
from the Start Procedure to the
preset Welding Procedure.
END OPTIONS
EFFECT / RANGE
Postflow Time:
Adjusts the time that shielding
0 to 10 seconds
gas flows after the welding out-
put turns off.
Burnback: 0 to .25
The burnback time is the
Seconds
amount of time that the weld
output continues after the wire
stops feeding. It prevents the
wire from sticking in the puddle
and prepares the end of the
wire for the next arc start.
Crater Procedure
Crater Procedure controls the
WFS and Trim for a specified
time at the end of the weld
after the trigger is released.
During the Crater time, the
machine will ramp up or down
from the Weld Procedure to
the Crater Procedure.
DESCRIPTION