Lincoln Electric POWER FEED IM916 Operator's Manual page 60

Dual wire feeder
Table of Contents

Advertisement

E-11
Error Codes for the Power Wave 455: Code 10675 and above.
ERROR CODES FOR THE POWER WAVE 455
The following is a list of possible error codes that the Power Feed™ 10M Dual Wire Feeder can output via the
display on this user interface.
Note: For any Err # listed below write down the error number for reference and try cycling power to see if the
error clears itself. If not, refer to the What to Do column for the given Err.
PRObLEMS
(SYMPTOMS)
Display shows any of the following:
Err 34
Err 35
Err 36
Err 37
Err 41
Err 43
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUbLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
POSSIbLE CAUSE
Capacitor "A" under voltage
(Left side facing machine)
Capacitor "B" under voltage
(Right side facing machine)
Thermal error
Softstart error
Secondary overcurrent error
Capacitor delta error
POWER FEED™ 10M DUAL WIRE FEEDER
Excess voltage on the main capaci-
tors. May be caused by improper
input configuration.
When accompanied by an undervolt-
age error on the same side, it indi-
cates no capacitor voltage present
on that side, and is usually the result
of an open or short in the primary
side of the machine.
Indicates over temperature. Usually
accompanied by Thermal LED.
Check fan operation. Be sure
process does not exceed duty cycle
limit of the machine.
Capacitor precharge failed. Usually
accompanied by codes 32-35.
The secondary (weld) current limit
has been exceeded. When this
occurs the machine output will phase
back to 100 amps, typically resulting
in a condition referred to as "noodle
welding"
NOTE: For the Power Wave 455/R
the secondary limit is 570 amps for
the standard stud, and 325 amps for
the STT stud and all single phase
operation.
The maximum voltage difference
between the main capacitors has
been exceeded. May be accompa-
nied by errors 32-35.
CAUTION
RECOMMENDED
COURSE OF ACTION
E-11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power feed 10m

Table of Contents