No.
Part name
Fan motor
1) Follow to the procedure in the item
2) Loosen the set screw of the cross flow fan.
3) Remove two fixing screws of the motor
4) Pull the fan motor outward.
ˆ
Cross flow fan
1) Follow to the procedure in the item
2) Remove the heat exchanger fixing holder
3) Loosen the set screw of the cross flow fan.
4) Lift the left side of the heat exchanger, and
Procedures
band (Right), and then remove the motor
band (Right).
In assembling work, install the fan motor
as follows.
• When assembling the fan motor, the fan
motor must be installed in such a way
that the fan motor leads will be taken out
is positioned at the bottom front.
• After assembling the two hooking claws
of the motor band (right) into the main
body, position the fan motor, insert it, and
then secure the motor band (right) using
the two fixing screws.
Fan motor leads
by removing the two fixing screws used to
secure it.
pull out the cross flow fan.
www.ilmalämpöpumput.com
ƒ
.
Secure using
ng
the fixing screw
crew
Screw
Motor band (Right)
d (Right)
Screw
Secure using
ng
the fixing screw
crew
.
– 95 –
Remarks
Raise the
left side
Pull out here