Overview
The following are rules for meter selection for Epipe, IES and VPRN services: (NOTE: these
rules apply to IES services when PIM is not enabled in the service).
The following are rules for meter selection for IES services when PIM is enabled in the service
and describes the usage of meters when meter "11" is not configured in the policy:
The following are rules for meter selection for IES services when PIM is enabled in the service
and when meter "11" is defined in the policy:
Page 206
7210 SAS-X and 7210 SAS-R6 OS Quality of Service Guide
If a FC is created with an explicit unicast meter and explicit multicast meter, use the
unicast meter for unicast traffic and multicast meter for all other kinds of traffic.
If a FC is created with an explicit unicast meter, an explicit broadcast meter, and an
explicit multicast meter, user these meters for unicast, broadcast and multicast traffic types
respectively. Unknown unicast traffic type will use the explicitly defined multicast meter.
If a FC is created with an explicit unicast meter, an explicit broadcast meter, an explicit
unknown-unicast meter, and an explicit multicast meter, use these meters for unicast,
broadcast, unknown-unicast and multicast traffic types respectively.
A multipoint meter cannot be used. A multipoint meter configured in a policy is not used
when the policy is applied to a SAP in an Epipe service.
All FCs associated with a meter always use the unicast meter.
If a FC is created without explicit meters, the default meter "1" is used for unicast traffic
and multicast traffic.
If a FC is created with an explicit unicast meter, that meter is used for unicast traffic and
for multicast traffic.
If a FC is created with an explicit unicast meter and explicit multicast meter, use the
unicast meter for unicast traffic and multicast meter for multicast traffic.
If a FC is created without explicit meters, use the default meter "1" for unicast traffic and
default meter "11" for multicast traffic.
If a FC is created with an explicit unicast meter, use that meter for unicast traffic and use
default meter "11" for multicast traffic.
If a FC is created with an explicit unicast meter and explicit multicast meter, use the
unicast meter for unicast traffic and multicast meter for multicast traffic.