Toshiba MMY-MAP0804HT8JP Service Manual page 100

Air-conditioner (multi type)
Hide thumbs Also See for MMY-MAP0804HT8JP:
Table of Contents

Advertisement

D
N
I
e t
m
High-ceiling adjustment
(Air flow selection)
5d
Built-in filter
Static pressure selection Concealed duct standard
Timer setting
60
(wired remote controller)
1-way cassette (SH)
Value
Type
0000
Standard (factory default)
0001
High-ceiling (1)
0003
High-ceiling (3)
2-way cassette
Value
Type
0000
Standard (factory default)
0001
High-ceiling (1)
0003
High-ceiling (3)
* The high-ceiling installation of model AP007 to AP012 can only be
undertaken when the combined capacity of the indoor units connected is
100% or less than the capacity of the outdoor unit.
Do not proceed with high-ceiling installation if this limit is exceeded.
4-way cassette
Type
Value
Air flow at outlet
4 directions 3 directions 2 directions 4 directions 3 directions 2 directions
Standard
0000
2.7 m
(factory default)
0001
High-ceiling (1)
0003
High-ceiling (3)
Type
Value
Air flow at outlet
4 directions 3 directions 2 directions 4 directions 3 directions 2 directions
Standard
0000
3.0 m
(factory default)
0001
High-ceiling (1)
3.3 m
0003
High-ceiling (3)
3.6 m
Ceiling
V
a
u l
e
T
y
p
e
0000
Standard (factory default)
0
0
0
1
H
g i
h
c -
i e
n i l
g
(
) 1
2-way cassette
0000: Standard filter (factory default)
0001: Super long-life filter
4-way cassette
0000: Standard filter (factory default)
Ceiling
0000: Standard filter (factory default)
Concealed duct standard
0000: Standard filter (factory default)
0001: High-performance filter (65%, 90%)
0000: Standard (factory default)
0001: High static pressure 1
0003: High static pressure 2
0006: Low static pressure
0000: Available (can be performed)
D
e
s
c
i r
t p
o i
n
AP015, AP018
3.5 m or less
4.0 m or less
4.2 m or less
AP007~AP030
2.7 m or less
3.2 m or less (*)
3.8 m or less (*)
AP009~AP012
AP015~AP018
2.8 m
3.0 m
2.8 m
3.2 m
3.5 m
AP024~AP030
AP036~AP056
3.3 m
3.6 m
3.0 m
3.5 m
3.8 m
3.3 m
3.8 m
3.6 m
A
P
0
1
5
~
A
P
3.5 m or less
4
0 .
m
r o
e l
Slim Duct
0000: Standard (factory default)
0001: High static pressure 1
0003: High static pressure 2
0006: High static pressure 3
0001: Unavailable (cannot be
performed)
– 99 –
A
t
0000: Standard
AP024
3.8 m or less
4.0 m or less
4.2 m or less
AP036~AP056
2.7 m or less
3.0 m or less
3.5 m or less
3.2 m
3.5 m
3.5 m
3.8 m
3.8 m
3.3 m
3.6 m
3.5 m
3.8 m
3.8 m
0
5
6
s s
0000: Available
s
h
p i
m
e
t n

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents