Honeywell ADEMCO VISTA-48A Installation And Setup Manual page 52

Hide thumbs Also See for ADEMCO VISTA-48A:
Table of Contents

Advertisement

Installation Instructions
"C"
01 Enter Zn No.
12
01 Output Action
Close for 2 sec
1
Enter Output No.
R02
02
02
A E P TRIG
R02 1 1
3
ZL=1
5-12
Zone Number
Output Action
0-6 = see list at right
Output Number
01-16 = output no.
17-18 = on-board triggers
Summary Screen
If zone number was selected, this screen appears.
Enter the desired zone number associated with this output number.
Press [∗] to continue.
Enter the zone event that will activate this output.
01 Enter Event
Restore
0
Press [∗] to continue to the "Output Action" prompt
Enter the desired device action as listed below. Press the [∗] key to
continue.
0 = off
1 = Close for 2 seconds
2 = Close and Stay Closed
3 = Continuous Pulse on & off (1 sec ON, 1 sec OFF)
Enter the device output number (programmed in *79 Menu Mode)
you want associated with this output.
Press [∗] to continue.
A summary screen appears showing the programmed settings.
Press [∗] to continue.
0 = restore; 1 = alarm
2 = fault; 3 = trouble
4 = Change Device State
5 = Duration 1 (see data field *177)
6 = Duration 2 (see data field *177)