Dip Switches; Jumper Settings - Furuno FR-1505 MARK-3 Series Service Manual

Hide thumbs Also See for FR-1505 MARK-3 Series:
Table of Contents

Advertisement

4.1 DIP Switches

DIP switch S1 on the ARP Board (18P9004) changes the specifications of radars.
S1
OFF
Baud rate of
#1
ARPA output data:
4800 bps
Tracking model:
#2
A TRK 88 *1
#3
Not used
EEPROM memory
#4
clear at power-off
*1A TRK94 has faster tracking speed than A TRK88, but result in unsteady vector and track.

4.2 Jumper settings

Unit No.
Board Name
PTU Board, AC
03P9228C
PTU Board, AC
03P9228D
PTU Board, DC
03P9223C
Display
Unit
PTU Board, DC
03P9223D
TX-HV Board
HV-9017A
TX-HV Board
HV-9017B
RP Board
03P9259
ON
Baud rate of
ARPA output data:
9600 bps
Tracking model
A TRK 94 *1
Used
EEPROM memory
clear at power-on
Settings
JP1: Yes
JP2: Yes
JP3: Yes
JP4: No
JP10: Yes
C37 : 220uF
JP1: No
JP2: No
JP3: No
JP4: Yes
JP10: Yes
C37 : 220uF
JP7: No
JP8: No
JP9: No
JP10: Yes
JP19: X-C
JP20: X-C
K1: VSB
C37: 220uF
JP7: Yes
JP8: Yes
JP9: Yes
JP10: Yes
JP19: X-C
JP20: X-C
K1: VSB
C37: 220uF
JP1: 300 V
JP2: 330 V
JP1: 500 V
JP2: 330 V
JP1: Yes
4-2
S1
OFF
ON
#4
#1
Description
For 110 VAC specification
For 220 VAC specification
For 12 VDC specification
In addition to these settings, the connection on the
transformer T1 must be changed. See next page.
For 24/32 VDC specification
In addition to these settings, the connection on the
transformer T1 must be changed. See next page.
For 10 kW (FR-1510M3)
For 25 kW (FR-1525M3)
For the connection of the battery to back-up circuit
18P9004(ARP)
FR1710-SME-24