The temperature control is described below.
Vt
Temperature
˚C
V2
V1
HEATON-N
When Vt rises to V2 or more, the heater is turned off (by setting HEATON-N signal to LOW).
When Vt drops to V1 or less, the heater is turned on (by setting HEATON-N signal to HIGH). In
this way, the temperature can be kept within the predetermined range.
40990901TH Rev.1
ON
OFF
V2
176˚C
* The values V1 and V2 vary according to setting mode.
V1
175˚C
(Standard temperature)
ON
OFF
ON