Samsung RF265AARS RF266AARS RF26NBRS1RF265AABP RF266AABP RF26NBBP1RF265AAWP RF266AAWP RF26NBSH1RF265AASH RF266AASH Service Manual page 60

Bottom mount freezer
Table of Contents

Advertisement

TROUBLESHOOTING
8) If Pantry Room Damper Heater has trouble
ERROR Code
Measure the resistance
between - after
CN90 connector open 145ohm
Initial
MICOM
power On
#37
4.0V ~
condition
4.5V
Checking method of Pantry Room Damper
resistance CN91#1(Black)
**
: Open(wire disconnection, heater
disconnection) trouble 0 : Short trouble
7%
Damper
Damper
heater off
heater On
4.0V ~
0V
4.5V
#2(Brown)
Start
Start
NO
Is Damper Heater
normal?(about145ohm)
YES
YES
NO
Is MAIN PCB connector
(CN91) inserted correctly?
YES
YES
NO
Is the input voltage of
IC02 MICOM #37 normal?
YES
YES
Normal(recheck)
59
Replace Damper
Bad contact of connector/ insert correctly
1) Recheck the wire
2) Replace PCB MAIN

Hide quick links: