Displaying Technical Maintenance And Energy Savings Data - Beko DRYPOINT RA 1300-4400 eco Instructions For Installation And Operation Manual

Compressed air refrigeration dryer
Table of Contents

Advertisement

8.14.10 Displaying technical maintenance and energy savings data

Press the
button to access the dryer's menu of functions.
1-
Press the
button to display:
2-
The total percentage of energy savings for the main compressor,
2a-
with respect to its continuous operation at 100%.
The partial percentage (starting from the last time the counter was
2b-
zeroed) of energy savings for the main compressor, with respect to its
continuous operation at 100%.
The date the partial energy savings counter was last zeroed.
2c-
The total hours of dryer operation.
2d-
The total hours of main compressor operation at variable speed.
2e-
The total hours of secondary compressor operation (no. 1) at fixed
2f-
speed (if installed).
The total hours of secondary compressor operation (no. 2) at fixed
2g-
speed (if installed).
The hours remaining till the next service.
2h-
The partial hours of dryer operation, starting from the last time the
2i-
counter was zeroed.
With dryer stopped (STANDBY mode), press the Reset button to reset the
3-
count of the hours remaining before the next service (parameter SrV 
default 8000 hours). This function is useful in the case of maintenance
carried out on the dryer before the hours remaining till the next service have
lapsed. This is a password-protected function to prevent the counter being
reset accidentally.
Press the Reset button to zero the partial energy savings counter.
4-
Confirm the counter is to be zeroed with OK, or exit without zeroing with
5-
Cancel.
Press the
button to return to the previous screen at any time.
6-
DRYPOINT® RA 1300-4400 eco
Technical description
2a-
2d-
2b-
2f-
2c-
2h-
4-
5-
6-
1-
2-
2e-
2g-
2i-
3-
25

Advertisement

Table of Contents
loading

Table of Contents