Technical description
ID
DrC
Sets the service warning intervention threshold
HdA
Hdd
Select if high dew point service warning
HdS
Sets the hours remaining till the next service
SrV
Sets the temperature/pressure units of measurement
°C = Temperature in °C and pressure in bar
SCL
°F = Temperature in °F and pressure in psi
Enables/disables automatic dryer restart after restoring the
AS
Yes = the dryer restarts automatically after restoring the electricity
No = The dryer must be restarted using the
Enables/disables the electronic condensation drain fault to be reset
Ard
Selects the switching logic for the alarm contact on the DCM50
ACM
1 = any alarm and high dew point
2 = any alarm and any service warning
3 = any alarm
28
Description
- Dryer Remote Control -
Enables/disables dryer remote control
- High Dewpoint Alarm -
high dew point
- High Dewpoint Delay -
Sets the service warning delay time
high dew point
- High Dewpoint Alarm Stop -
- Stops the dryer (Yes)
- Does not stop the dryer (No)
- Service Setting -
NOTA : 00.0 = counter disabled
- Auto Restart -
electricity supply.
supply (if it had been started)
- Auto Reset Service Drain -
automatically.
Yes = reset automatically
No = reset manually
- Alarm Contact Management -
control unit's main module:
Limits
Local /
Remote
0...25.0°C
or
32...77°F
1...20
minutes
Yes / No
12.0
(x1000)
hours
°C / °F
Yes / No
button.
Yes / No
1...3
DRYPOINT® RA 1300-4400 eco
Factory
Scale
setting
-
Local
0.5°C
20.0°C
or
or
1°F
68°F
1
15
minute
minutes
-
No
0.5
8.0
(x1000)
(x1000)
hours
hours
-
°C
-
No
-
Yes
1
1