Only qualified personnel can use and service electrically powered devices. Before attempting any
maintenance:
Ensure that no part of the machine is powered and is locked out of the electrical mains by following
proper "Lock-out, Tag-out" procedures and requirements.
Ensure that no part of the dryer is under pressure by isolating the dryer from the compressed air
system.
Any change to the machine or to the standard operating parameters (see Section 3.1), if not previously
verified and authorized by the manufacturer, in addition to creating a potentially dangerous situation, will
void the warranty.
Do not use water to extinguish fire on the dryer or in the surrounding area.
2.

INSPECTION AND TRANSPORTATION

All dryers are tested and inspected at the factory prior to shipping. Thoroughly inspect and verify the integrity of the
packaging upon receipt and note any damage on the freight bill. Place the unit as close as possible to the installation
point before unpacking the contents and inspect for concealed damage. Freight claims are to be filed with the carrier
immediately and the manufacturer's technical service department notified thereafter.
To move the packaged unit, we suggest the use of a suitable crane by the lifting lugs. We do not recommend
moving the unit by any hand operated or manual mechanism.
Handle with care. Heavy blows could cause irreparable damage.
Even when packaged, keep the machine protected from severe weather.
The packaging materials are recyclable. Each material must be properly disposed in a manner complying
with the rules and regulations of the local municipality government.
3.

TECHNICAL SPECIFICATIONS AND GENERAL FUNCTION

3.1

Technical Data by Model Size

Nominal dryer ratings adhere to the following inlet conditions @ seal level per ISO 7183, Table 2, Option A2:
Inlet Compressed Air Temperature 100 °F (38 °C)
Inlet Compressed Air Pressure 100 psig (7 bar)
Ambient Air Temperature 85 °F (30 °C)
Inlet Compressed Air Relative Humidity 100% (Saturated)
SCFM is defined as the flow rate of free air in cubic feet per minute measured at 14.5 psia (1.013 bar) at 68 °F (20 °C)
temperature with 0% relative humidity (0 WVP).
DRYPOINT® XFi
Standard Outlet Pressure Dew Point*
Min. / Max. Ambient Temperature
Min. / Max. Inlet Air Temp
Min. / Max. Inlet Air Pressure
Electrical Power Supply
Standard Desiccant Type
*Standard dew point performance based on nominal conditions.
DRYPOINT XFi 1000 manual_revA EN
-40°F
40°F / 120°F
40°F / 120°F
60psig / 150psig
460Vac / 3ph / 60Hz
1/8" Activated Alumina